background image

2

 

98MANAL574   Rev. F 

PRODUCT OVERVIEW

 

All information contained in this document is representative of a 

standard

 Model 574.  If the product you ordered has 

special requirements or modifications, refer to the Laser Marked information on the product and your purchase order 
for possible alteration to the product’s configuration.  Failure to verify product configuration before installation may 
cause permanent product damage, and in most cases, void the manufacturer’s product warranty.  If you are unsure 
or have questions about your product, please contact our Application Engineers for assistance.  

Remove and retain all instruction manuals and performance certificates that are shipped with the product.  These 
documents provide important information on the product’s calibration, operation, safety precautions, recommended 
maintenance, re-calibration requirements, repair service instructions and warranty information.  These documents are 
updated from time to time as changes to the product occur and should be reviewed at receipt so that proper and safe 
installation can occur.  

INSTALLATION DATA - VIATRAN MODEL 574

Note: The drawing below is for informational purposes only and is not to scale.

All dimensions are nominal, in inches and for reference purposes only.

CONNECTION DIAGRAMS

Recommended Mounting

250O

Summary of Contents for 574

Page 1: ...L574 Rev F INSTALLATION DATA MANUAL MODEL 574 PRESSURE TRANSMITTER 199 Fire Tower Drive Tonawanda NY 14150 Int l 1 716 629 3800 Toll Free 1 800 688 0030 Fax 1 716 693 9162 www viatran com solutions viatran com ...

Page 2: ...ct our Application Engineers for assistance Remove and retain all instruction manuals and performance certificates that are shipped with the product These documents provide important information on the product s calibration operation safety precautions recommended maintenance re calibration requirements repair service instructions and warranty information These documents are updated from time to t...

Page 3: ...ble damage 13 To preserve the integrity of the hermetic design the units have no field replaceable or repairable parts BASIC OPERATION INTERNAL CALIBRATION CIRCUIT See Maintenance and Repair for calibration frequency recommendations Note The casting of the module has raised numbers at the adjustment screw positions Those numbers reflect the following function of the assigned screw Screw 1 Top Left...

Page 4: ... mists dusts or contaminants could cause them to become frozen in place causing the module to become locked and non usable This would render external adjustment difficult at best Replacement magnets are available if this problem occurs Hence a visual inspection of the calibration pots should take place on a 2 to 4 week schedule or when extreme environmental conditions require it 4 NEVER Strike a p...

Page 5: ...lve 12 months from the date of shipment provided that Viatran s obligation hereunder shall be limited to correcting any defective workmanship and or replacing any defective material f o b factory No allowance will be made for any expense incurred for correcting any defective workmanship and or material without written consent by Viatran This warranty is in lieu of all other warranties expressed or...