Viand PRO Aria Installation And User Manual Download Page 4

Aria Ceiling Hood Fitting Instructions and Operation

Safety instructions

Thank you for purchasing this cooker hood. Please read the instruction manual

carefully before you use the cooker hood, and keep it in a safe place.

The installation work must be carried out by a qualified electrician or

competent person. Before you use the cooker hood, make sure that the

voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly

the same as the voltage

(V) andthefrequency (Hz) in your home.

The manufacturerandtheagentwillnotbearanyresponsibility forthe damage

caused by inappropriate installation and usage.

Never let children operate the cooker hood.

The cooker hood is for home use only. It is not suitable for barbecues, Roast

shopand commercial purposes.

The cooker hood and its filter mesh should be cleaned regularly in order to

keep it in good workingorder.

Before cleaning, switch the power off at the main supply.

Clean the cooker hood according to the instruction manual and keep the

cookerhood from the danger of burning.

Prohibit putting the cooker hood by fire.

If there is any fault with the appliance, please call the service department to

request a service engineer.

This appliance can be used by children aged from 8 years and above and

persons with reduced physical, sensory or mental capabilities or lack of

experience and knowledge if they have been given supervision or

instruction concerning use of the appliance in a safe way and understand

the hazards involved. Children shall not play with the appliance. Cleaning and

user maintenance shall not be made by childrenwithoutsupervision.

If the supply cord is damaged, it must be replaced by the manufacturer, its

service agent or similarly qualified persons in order to avoid a hazard.

The instructions shall state the substance of the following: there shall be

adequate ventilation of the room when the range hood is used at the same

time as appliances burning gas or other fuels (not applicable to appliances

that only discharge the air back into the room).

Do not flambé under the range hood. Accessible parts may become hot

when used withcookingappliances.

Important Hints on Installation

The air must not be discharged into aflue that is used for exhausting fumes from

appliances burning gas or other fuels (not applicable to appliances that only

discharge the air back into the room).

Regulations concerning the discharge of air have to be fulfilled.

Summary of Contents for Aria

Page 1: ...Aria Ceiling Hood Fitting Instructions and Operation Aria Ceiling Hood Installation And User s Manual VP CH93WHTSS 2 VP CH93BLKSS 2 VP CH93WHT 2 VP CH93BLK 2 ...

Page 2: ...Aria Ceiling Hood Fitting Instructions and Operation ...

Page 3: ...utions mentioned in the instruction manual is not covered by our warranty and any liability Content Contents 3 Safety Instructions 4 Installation 6 Recirculation Mode 8 Changing the Filter 8 Operation 9 Remote Control 10 Technical Data 11 Trouble shooting 12 Cleaning And Care 13 Hints On Disposal 13 Declaration of conformity This product is conform to the following EuropeanDirectives 2014 30 EU EM...

Page 4: ...liance please call the service department to request a service engineer This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall notplay with...

Page 5: ... that a sufficient supply of fresh air is guaranteed and that the air can circulate An air supply extractor box alone does not ensure compliance with the limit value Safe operation is only possible when the negative pressure in the room where the appliance is located does not exceed 4 Pa 0 04 mbar This can be achieved when the air required for combustion can flow through openings that are not clos...

Page 6: ...r Installation Preparation If you have an outlet to the outside your cooker hood can be connected as below picture by means of an extraction duct enamel aluminum flexible pipe or inflammable material with an interior diameter of 150mm Before installation turn the unit off and unplug it from the outlet The cooker hood should be placed at a distance of 65 150cm above the cooking plane for best effec...

Page 7: ...four holes inthelowercorners ofthe hood The brackets should be adjusted so that the lower edge of the extractor hood is flush with the ceiling Screw four screws through the four holes in the lower corners of the hood When mounting a non return valve it must be ensured that the valve can be opened freely If the valve cannot be opened freely it can reduce the suction power and increase the noise fro...

Page 8: ...on filter Open up the hinged door on the hood Remove the grease filters Plug the activated carbon filter into the unit and turn it in clockwise direction Repeat the same on the other side Make sure the filter is securely locked When activated carbon filter attached the suction power will be lower Replace the filter every 3 4 months for optimum operation If the extractor hood is used for recirculat...

Page 9: ...motor runs at high speed Switch the light on and off Setting the Lighting Colour In standby mode press and hold the LIGHT button to adjust the illumination color Use the button 3 to adjust one of the following light colors The lights will show the corresponding number L1 L9 Display Colour Display Colour L1 White L6 Purple L2 Red L7 Orange L3 Green L8 Cyan L4 Blue L9 Yellow green L5 Yellow ...

Page 10: ...is on to activate the timer mode The pre set time for the timer is 5 minutes When the timer has expired the cooker hood will automatically turn off To calibrate the remote control In standby mode long press the on off button on the hood panel for 3 seconds till it flashes then immediately press the on off button on the remote control to complete If the calibration was successful an acoustic signal...

Page 11: ...cy category G Grease separation 69 1 Grease separation category D Air flow 317 2m hr 411 1m hr Maximum air flow Qmax 411 1m h Airflow at boost setting N A A rated noise emission 54dB 59dB Power consumption off Po 0 4W Power consumption standby Ps Power 0 38W Consumption lighting system W 10 0W Connected load 85W Illuminant LED Power consumption per illuminant unit 2 5W Voltage frequency 220 240 V ...

Page 12: ... out Replace the bulb with correct rating Power cord loose Plugin to the power supply again Serious vibration of the unit The fan blade is damaged Switch of the unit and Repair by qualified service personnel only The fan motor is not fixed tightly The unit is not hung properly on the bracket Takedown the unit and check whether the bracket is in proper location Suction performance not good Too long...

Page 13: ... the European waste regulation 2012 19 EU this symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment a...