10
2.3
Using the Ethernet Optical Transceiver
An Ethernet connection is made to each Transceiver at the respective D-connector on the rear of the
ViaLite
19” rack chassis, via the RJ45 to D-connector adapter cable together with the RJ45 coupler.
Two fibre optic cables are necessary for the operation of the Ethernet Optical Link. Connect the optical
fibre connector marked
T
on one module to
R
on the other module, and vice-versa.
Note:
It is not possible to establish a link by connecting a 100Mb/s Ethernet Optical Transceiver to a
10/100/1000Mb/s auto switching Ethernet Optical Transceiver as the fibre interfaces are incompatible.
To establish a successful working link, two modules with the same speed specifications must be used.
2.3.1
Front Panel Indicators
The Transceiver has a number of front panel LEDs for indication of essential status information of the
module. The following table shows the operation of the front panel LEDs :
100Mb/s Ethernet Optical Transceiver
LED
Function
Pwr
Illuminates to indicate power supply to the Transceiver.
LINK
Steady ON when both of the attached fibres are operational at opposite
ends, and blinking when receiving a remote fault signal from the other end.
Fibre Port
RX/ACT
Blinking indicates receiving packets.
LINK
Steady ON when the attached Ethernet cables are operational at their
respective other ends.
Copper
Port
RX/ACT
Blinking indicates receiving packets.