Introduction 

The 

ViaLiteHD

 Summary alarm module is used to monitor 

ViaLiteHD

 equipment fitted in the same rack.  It is able to report alarms by front 

panel visual indication, audio alarm  and by status of it’s on board relays.  There are two form  C relays, both accessible at the rear of the 
module; one relay is also routed to the cabinet backplane. 
 
The summary alarm module maybe configured, so that it

’s on board processor automatically senses and alarm only active module; or it may 

be configured via manual DIP switches both monitoring and controlling modules 
 
The module has an on board resistive load, this can be configured via DIP switches to ensure the power supplies meet their minimum load 
requirement.  See your 

ViaLiteHD 

Rack Handbook for more details.  

 
 
 

 

Internal architecture  

 
 

 

 
 
 

Key features are: 
 

 

The CPU monitors all rack alarm outputs 

 

Compatible with either 1U or 3U rack 

 

The CPU controls all module outputs 

 

The module fits in 

ViaLiteHD

 rack chassis 7HP slot,  

o

 

In a 1U HRK1 rack it fits in slot 3 

o

 

In a 3U HRK3 rack it fits in slot 14 

 

DIP switches available for manual alarm screening, slots 1-13 and slots 15,16 

 

I2C bus is used at start up to monitor active slots for automatic alarm masking 

 

Two dry contact relays, both accessible on module rear connector, one wired in parallel to the rack chassis connector 

 

Front panel LED indication of rack summary status. 

 

Front panel buzzer, giving audio alarm when fault is active 

 

Front panel ACKNOWLEDGE switch 

 

Different indication for active ALARM and acknowledged ALARM  

 

The DC input power feed (+12 volts) is protected by a set resetable fuse. 

 

The internal 5V is generated by linear regulator 

 

 

PSU

DIP 

switch

bank

CPU

Load

4 * 3W

Mute

switch

Buzzer

LEDs

I2C

Relay1

Relay2

Alarm
inputs

NO

COM
NC

NO

COM

NC

NO

COM
NC

MS_X

I2C

15

Alarm_X

13

B

a

c

k

p

la

n

e

M

o

d

u

le

 r

e

a

r

B

a

c

k

p

la

n

e

F

ro

n

p

a

n

e

l

Summary of Contents for HRC-2-HB-5

Page 1: ...e User Guide HRC 2 HB 5 CR4645 10 12 2020 Pulse Power Measurement Ltd 65 Shrivenham Hundred Business Park Watchfield Swindon Wiltshire SN68TY UK Tel 44 0 1793 784389 Fax 44 0 1793 784391 Email sales vialite com Web www vialite com ...

Page 2: ...e Precautions for handling electro static sensitive devices should be observed when handling all ViaLiteHD modules Technicians should ensure that they use effective personal grounding i e ESD wrist strap etc when servicing the equipment Any equipment or tools used should be grounded to prevent static charge build up Good practice should be observed at all times for reference see relevant standards...

Page 3: ...eplaced module 8 Front panel acknowledge switch slot alarm inactive with no I2C response fail module 8 Rear panel 8 2 3 1 Rear panel module rear connections 8 2 3 2 Rear panel backplane relay connection 8 User configuration DIP switches 8 2 4 1 User configuration DIP switches alarm masking SW2 and SW3 9 2 4 2 User configuration DIP switches load resistors SW5 10 3 SETTING UP THE SUMMARY ALARM MODU...

Page 4: ...e The CPU monitors all rack alarm outputs Compatible with either 1U or 3U rack The CPU controls all module outputs The module fits in ViaLiteHD rack chassis 7HP slot o In a 1U HRK1 rack it fits in slot 3 o In a 3U HRK3 rack it fits in slot 14 DIP switches available for manual alarm screening slots 1 13 and slots 15 16 I2C bus is used at start up to monitor active slots for automatic alarm masking ...

Page 5: ...of other equipment When fitted in an HRK3 rack chassis it must be fitted in slot 14 this is the only slot to have communication with all other slots ViaLiteHD and ViaLite Classic compatibility The ViaLiteHD summary alarm module will not control or monitor ViaLite Classic equipment Its dry contact relay circuits will be compatible with circuits used on previous ViaLite Classic equipment ...

Page 6: ...op To install a 7HP Standard module Push the release button of the module handle down and simultaneously pull the top of the handle forwards Align the module upright and perpendicular to the front face of the rack chassis so that the PCB slides into the crow s feet card guides top and bottom Gently push the module down its guide applying pressure via the handle you may also apply pressure between ...

Page 7: ...ctive The buzzer operates with a nominal frequency of 2 4kHz the tone is modulated 2 2 4 Front panel acknowledge switch The ACKNOWLEDGE switch is housed on the front panel this is used to acknowledge alarms It works in a number of different modes after the alarm is generated depending on the status of the slot module when the acknowledge switch is hit After the ACKNOWLEDGE switch is pressed the su...

Page 8: ...vailable at the rear of the module The three connections for each relay are NO Normally open COM Common NC Normally closed Connections from Relay 1 are also connected in parallel to the rack chassis backplane The rear panel provides interconnections for two dry contact relays The many be accessed via a six way screwless connector it is suitable for use with 14 22 AWG wire J2 Name ALARM OFF ALARM O...

Page 9: ...rack Name 3U rack OFF NO Position 1 Unused SET OFF Slot 6 Slot 6 alarms masked Normal operation Position 2 Unused SET OFF Slot 7 Slot 7 alarms masked Normal operation Position 3 Unused SET OFF Slot 8 Slot 8 alarms masked Normal operation Position 4 Unused SET OFF Slot 9 Slot 9 alarms masked Normal operation Position 5 Unused SET OFF Slot 10 Slot 10 alarms masked Normal operation Position 6 Unused ...

Page 10: ...s to be active The module can provide a maximum load of 12 watts load this load can be switched in 3 watt steps Load 0 3 6 9 12 watts switched Control via switch selection using four DIP switches see section 2 4 Setting 3U rack only 1 or 2 modules fitted all four switches ON 3U rack only 3 or 4 modules fitted three switches ON 3U rack only 5 or 6 modules fitted two switches ON 3U rack only 7 or 8 ...

Page 11: ...anual alarm masking 2 Set all other DIP switches of SW2 and SW3 to OFF Unpopulated slots will not respond to the I2C pole therefore these will all be masked When in automatic mode manual alarm masking DIP switches SW2 positions 1 8 SW3 positions 2 8 are ignored Setting the load DIP switches Detail of the DIP switch positions are given in section 2 4 2 If you wish to activate any of the resistive l...

Page 12: ...m tip to push the catch of the 6 way relay connector Wire cutters and stripper to prepare wires for insertion into the 6 way relay connector Suitable stranded 14 22 AWG wire to interface to the 6 way relay connector Full set up details are given in section 3 Site requirements The site will require the following services to make full use of the ViaLiteHD equipment Power source of rack chassis 19 en...

Page 13: ...PULSE POWER MEASUREMENT LTD 13 5 Mechanical Dimensions Weight 260g Typical 131mm 36mm 204mm ...

Page 14: ...PULSE POWER MEASUREMENT LTD 14 6 Part Numbering For part numbering please refer to the relevant datasheet which can be found on our website or contact us ...

Page 15: ...tch selection 4 switches 3 watts per switch Electrical load 0 3 6 9 12 watts Alarm monitoring Manual masking DIP switch selection Automatic masking via I2C sensing at start up Alarm sensing via backplane open collector alarm 13 modules plus 2 power supplies Buzzer frequency 2 4kHz Rear relay port Connector type Screw less 6 terminal connector Wire gauge 14 22 AWG 0 33 2 08 mm2 Relay Relay Type For...

Page 16: ...Buzzer is sounding A connected modules has an ALARM Fix alarming module OR Press the front panel switch to ACKNOWLEDGE the alarm This will mute the buzzer and change status LED to solid RED Status LED is solid RED A connected modules has an ALARM The alarm has already been acknowledged The ViaLiteHD range is precision engineered and calibrated for optimum performance and accuracy before dispatch I...

Page 17: ... Internet protocol IP3 Third order intercept point kg Kilo gram kHz Kilo hertz LAN Local area network LASER Light amplification by stimulated emission of radiation LC PC Lucent connector physical contact LED Light emitting diode LNA Low noise amplifier LNB Low noise block m Metre mA Milli ampere Max Maximum MHz Mega hertz Min Minimum mm Milli metre mV Milli volt NC Normally closed NF Noise figure ...

Page 18: ...hall be as stated in document F292 PPM Manufactured Product Warranty which is available at https ppm co uk warranty periods Extended warranty options are available at the time of purchase Prior to returning any goods for warranty or non warranty repairs please contact PPM ViaLite Communications for a returns reference ...

Page 19: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense PULSE POWER MEASUREMENT LTD 20...

Reviews: