100C Air Compressor Kit

COMPRESSOR APPLICATION GUIDE

To ensure that you get the highest level of satisfaction from your compressor performance, refer to 

information below: 
VIAIR COMPRESSOR REFERENCE CHART

COMPRESSOR SERIES 

MAX. WORKING 

DUTY CYCLE

 

PRESSURE   

(100 PSI @ 72°F)

090 SERIES 

120 PSI  

9%  

 

092 SERIES 

120 PSI  

9%  

095 SERIES 

120 PSI  

9%  

097 SERIES 

130 PSI  

10%  

098 SERIES 

130 PSI  

10%  

100 SERIES 

130 PSI  

15%  

250 IG SERIES 

150 PSI  

100%  

275 SERIES 

150 PSI  

25%  

280 SERIES 

150 PSI  

30%  

325 SERIES 

150 PSI  

33%  

330 IG SERIES 

150 PSI  

100%  

350 SERIES 

150 PSI  

100%  

380 SERIES 

200 PSI  

100%      

 

 

55% @ 200 PSI

400 SERIES 

150 PSI  

33%  

420 SERIES 

150 PSI  

33%  

425 SERIES 

175 PSI 

    33% @ 175 PSI 

 

 

 

50%

444 SERIES 

200 PSI  

100%     

 

 

50% @ 200 PSI

450 SERIES 

150 PSI  

100%  

450 IG SERIES 

150 PSI  

100%  

460 SERIES 

150 PSI  

100%  

480 SERIES 

200 PSI  

100%  

 

 

 

50% @ 200 PSI

485 SERIES 

200 PSI  

100%  

 

 

 

100% @ 200 PSI

ABOUT COMPRESSOR DUTY CYCLE:

Duty cycle refers to the amount of time a compressor can be
operated in a given time period at 100 

PSI, and a standard ambient temperature of 72° F. It is commonly expressed in percentage format: 

Compressor on time ÷ (on time + off time) = Duty Cycle %.

ONE-HOUR DUTY CYCLE   

MINUTES ON / 

(100 PSI @ 72°F) 

  MINUTES 

OFF

9% 

 

 

 

5 Min. On / 55 Min. Off

10% 

 

 

 

6 Min. On / 54 Min. Off

15% 

 

 

 

9 Min. On / 51 Min. Off

20% 

 

 

 

12 Min. On / 48 Min. Off

25% 

 

 

 

15 Min. On / 45 Min. Off 

30% 

 

 

 

18 Min. On / 42 Min. Off

33% 

 

 

 

20 Min. On / 40 Min. Off

50% 

 

 

 

30 Min. On / 30 Min. Off

100% 

 

 

 

1 Hour Run Time

NOTE: All compressors, regardless of rated duty cycle, require sufficient rest time in between cycles 

to allow for partial or complete heat dissipation. Heat dissipation rates may vary depending on 

ambient temperatures and operating conditions.

ABOUT RATED WORKING PRESSURE:

To ensure trouble free service life of your compressor, always operate compressor within rated 

working pressure of the compressor.  Never use a pressure switch with a higher cut-off pressure than 

compressor’s rated working pressure. 

Summary of Contents for 100C

Page 1: ... MANUAL 10010 100C Air Compressor standard mounting bracket CE Certified 10014 100C Air Compressor no leader hose or check valve CE Certified 10016 100C Air Compressor with Omega Bracket CE Certified 10019 100C Air Compressor Stealth Black with Omega Bracket CE Certified 100C Air Compressor Kit 100C P N 10014 100C P N 10016 100C P N 10019 Stealth Black 100C P N 10010 P N 10010 P N 10010 10014 1001...

Page 2: ...ur vehicle Each of our air compressors and parts have been carefully produced and packaged Before you begin installation please familiarize yourself with Installation Parts List Fig 1 of this manual Guidelines for Selecting Mounting Location The selection of proper mounting location for your air compressor will help ensure a long and trouble free compressor service life Please pay close attention ...

Page 3: ...et clamp into locked position 10 To remove hose from the hose bracket simply press down on the hose clamp release tab to release bracket clamp Fig 3 11 Connect compressor positive lead wire to one of the leads of your pressure switch 12 Make sure that your compressor setup is properly fused For appropriate fuse size refer to amp draw of compressor in the Specifications section of this manual 13 Al...

Page 4: ...r will automatically cut power to your air compressor should the internal operating temperature of the air compressor rise above safe levels during excessive use 4 Should at any time during use your air compressor automatically shuts off do not attempt to restart the air compressor Turn off power and allow unit to cool for about 30 minutes This will allow the Thermal Overload Protector to reset so...

Page 5: ...to the air compressor with bare hands during or immediately after use Leader hose and fittings connected to Leader Hose will become very hot during and after use If necessary wear heat resistant gloves to handle fittings air line and leader hose SPECIFICATIONS 100C AIR COMPRESSOR PART NUMBERS Part No 10010 100C Air Compressor standard mounting bracket CE Certified Part No 10014 100C Air Compressor...

Page 6: ...PSI ABOUT COMPRESSOR DUTY CYCLE Duty cycle refers to the amount of time a compressor can beoperated in a given time period at 100 PSI and a standard ambient temperature of 72 F It is commonly expressed in percentage format Compressor on time on time off time Duty Cycle ONE HOUR DUTY CYCLE MINUTES ON 100 PSI 72 F MINUTES OFF 9 5 Min On 55 Min Off 10 6 Min On 54 Min Off 15 9 Min On 51 Min Off 20 12 ...

Page 7: ...r to area with less humidity or use water separator Compressor will not run 1 No power or power switch in OFF position 2 Blown fuse 3 Motor overheats 4 Faulty pressure switch if hooked up to a pressure switch 1 Make sure compressor switch is ON 2 Disconnect compressor from power source replace fuse Refer to Specifications section for correct fuse amperage 3 Let compressors cool off for about 30 mi...

Page 8: ...omplete warranty details please visit www viaircorp com warranty PLEASE NOTE THIS WARRANTY COVERS PRODUCT DEFECTS ONLY IT DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES AS RESULT OF MISUSE OR ABUSE This Manual is proprietary to VIAIR Corporation and no ownership rights are hereby transferred No part of the Manual shall be used reproduced translated converted adapted stored in a retrieval syste...

Reviews: