25
Holidays TO3 (only in a case, that it is activated)
Parameter
Function
Production settings
Min.
Max.
Units
661
Preselection
1
8
-
662
Start
-
01.01
31.12.
dd.MM
663
End
-
01.01
31.12.
dd.MM
668
Type of operation
Anti-frost protection
Anti-frost protection,
Dumping
hh:mm
Heating circuit 1
Parameter
Function
Production
settings
Min.
Max.
Units
710
Comfort temperature
20
Row 712
Row 716
°C
712
Dumping temperature
16
Row 714
Row 710
°C
714
Anti-frost temperature
10
4
Row 712
°C
720
The slope of the heating curve
1.5
0.10
4.00
-
730
Automatics summer/winter
18
---/8
30
°C
742
Req. T Start of space Thermostat
65
Row 740
Row 741
°C
855
Act.req.temp.of drying
---
0
90
°C
856
Actual date of drying
----
0
32
-
Comfort temperature
required space temperature, which will be maintained in the heating phase.
Dumping temperature
required space temperature, which will be maintained in the dumping phase.
Anti-frost temperature
setting the required anti-frost space temperature.
Heating curve slope
this value means the setting of the heating curve, see fig. 16
Automatics summer/winter
the temperature limit for the transition between the summer and the winter mode.
Req. T StartSpaceThermostat temperature, to which the boiler will heat in case that no outdoor sensor is used.
Act. req. temperature of drying temperature setting for the floor heating drying.
Actual date of drying
setting of the date of the floor heating.
Hot water
Parameter
Function
Production
settings
Min.
Max.
Units
1610
Nominal temperature
55
8
80
°C
Nominal temperature setting of the required comfort temperature of hot water.
The adjusted heating curve uses the required temperature in the space from 20 °C. If the required/space
temperature changes, the heating curve is also changed. The heating curve displays the required temperature into
the heating circuit in dependence on the corrected outdoor temperature.
At using the space devices QAA74, QAA75 etc. the heating curve is extra corrected by the parameters Adjusted
space temperature and Influence of space.
Fig.
№
. 17
Heating curve slope
Summary of Contents for VIADRUS K 5