![Viadrus AkuCOMBI 1000/200 L Operating And Installation Manual Download Page 9](http://html.mh-extra.com/html/viadrus/akucombi-1000-200-l/akucombi-1000-200-l_operating-and-installation-manual_1011382009.webp)
9
Technical parameters
Designation
AkuCOMBI 600/200 L
Spirals
solar
CH
The volume of external tank
l
400
The volume of HWS tank
l
200
Maximal allowable temperature
o
C
100
Maximal allowable pressure in the tank with heating
water
bar
3
Test pressure in the tank with heating water
bar
5
Maximal allowable pressure in the HWS tank
bar
6
Test pressure in the HWS tank
bar
10
Surface of heat exchanger
m
2
2.1
1
Volume of heat exchanger
l
12.8
5,8
Dimensions
Height of heating water connection
GS1
mm
250
Height of solar connection (return)
GS2
mm
350
Height sensor connection (solar)
GS3
mm
565
Height solar connection (supply)
GS4
mm
780
Height of CH connection (return)
GS5
mm
1060
Height of sensor connection (CH)
GS6
mm
1335
Height of CH connection (inlet)
GS7
mm
1560
Height of other source connection (return)
GS8
mm
360
Height of other source connection (inlet)
GS9
mm
760
Height of other source connection (return)
GS10
mm
1160
Height of other source connection (inlet)
GS11
mm
1560
Height of equipment
L
mm
1920
Tank diameter (without insulation)
Ø
mm
700
Diameter with insulation
Ø
mm
900
Insulation made of hardened polyurethane
foam
mm
100
External shell
skay
Hydraulic connections
Heating water connection
internal
thread
1”
Solar circuit (supply / return branch)
internal
thread
1”
CH circuit (supply / return)
internal
thread
5/4“
Solar circuit (supply / return)
internal
thread
1”
E-coupling (heating element)
internal
thread
1 1/2”
Sensor Connection
internal
thread
3/4"
Cover of sensor
internal
thread
1/2"
Cold water / hot water
external
thread
3/4"
Circulation
external
thread
3/4"
Magnesium Anode
plug
5/4”
Weight (empty)
kg
295