![Vexar CD36T-M Owner'S Operation And Installation Manual Download Page 33](http://html1.mh-extra.com/html/vexar/cd36t-m/cd36t-m_owners-operation-and-installation-manual_1010624033.webp)
www.desatech.com
118531-01C
33
HI
LO
OF
F P
ILO
T
O
N
Figure 58 - Removing Mounting Screws,
Regulator, Tower, and Diaphragm/Spring
Components
Mounting
Screws
Pressure
Regulator
Tower
Diaphragm/
Spring
Components
GAS CONTROL CONvERSION
Convert gas control by swapping out valve
regulator portion of gas valve.
1. Using a Torx T20 or slotted screwdriver,
remove and discard three mounting
screws, pressure regulator tower, and
diaphragm/spring components (see
Figure 58).
2. Insure that rubber gasket is properly
positioned on new pressure regulator
assembly. Install LP pressure regulator
assembly to valve using the new mount
-
ing screws supplied with the kit. Tighten
screws securely (approximately 25 in-lbs.)
(see Figure 59).
3. Install identification label enclosed with
gas valve regulator to valve body, where
it can easily be seen (see Figure 59).
CONVERSION
INSTRUCTIONS
Continued
OF
F P
I
LO
T
O
N
Figure 59 - Installing Pressure Regulator
Assembly
Mounting
Screws
Rubber
Gasket
Identification
Label
CLEANING AND
MAINTENANCE
WARNING: Turn off fireplace
and let cool before cleaning.
CAUTION: you must keep
control areas, burners and
circulating air passageways of
fireplace clean. Inspect these
areas of fireplace before each
use. Have fireplace inspected
yearly by a qualified service
person. Fireplace may need
more frequent cleaning due to
excessive lint from carpeting,
bedding material, pet hair, etc.
GLASS DOOR
WARNING: Handle glass
door panel with care. Do not
strike, slam or otherwise abuse
glass. Do not operate fireplace
with the glass door unlatched,
removed, cracked or broken.