Voltage
Built-in batteries
: 2 V to 6.3 V/DC
External batteries / adapter
: 10 V to 30 V/DC
Current
Built-in batteries
: Display ‘ON’ 98 mA
Display ‘OFF’ 0,064 mA
External batteries 12 V/ adapter : Display ‘ON’ 95 mA
Display ‘OFF’ 21 mA
External batteries 24 V
: Display ‘ON’ 55 mA
Display ‘OFF’ 8 mA
Temperature
Operating temperature range
: 0˚C ... +40˚C
Storage temperature range
: -20˚C ... +60˚C
Pressure sensor
Indicating range
: 950 hPa - 1070 hPa
Linearity of indication
(with reference to sea-level)
: +/- 1 hPa
Temperature stability
: +/- 2 hPa (0˚C ... +40˚C)
Time accuracy
: +/- 4 secs. per month
Display and curve plotting
Active viewing area on
display panel
: 92 x 74 mm
Graphic resolution of display
: 160 x 128 pixel
Timescale
: 24 hours or 1 week
Pressure-scale window
(segment overall range)
: 20 hPa over 24 hours
120 hPa over 1 week
Resolution of pressure curve
: 0.2 hPa per pixel
Pressure resolution in
digital display
: 0.1 hPa
Weight
: 0.5 kg
Dimensions (W x H x D)
: 155 x 135 x 81 mm
Note: 1 hPa = 1 mbar
10.0801
33
Baroscope
ENGLISH
8 Technical data