090140.01
13
vetus®
Battery charger BC12051
4
th
Stage: Top-Off Charge:
Under this stage, the charger will shut off au-
tomatically when the battery is 100% charged.
The charger will monitor the battery voltage
continually to decide whether a new charge
pulse should come. The purpose of this stage
is
to fully charge the battery without over-
charging the battery
.
5
th
Stage: Maintain Floating:
If the voltage drops below the pre-set level
by battery self-discharge, the charger starts a
charge pulse with a low current t
o maintain
the battery in full-charge status
. The cycle is
repeated as long as the charger is in “Maintain
Floating” mode.
7 Charging capacity
Battery Capacity
Charging Time
Ah
CCA
35 - 45
200
3.5 hrs
40 - 50
300
6 hrs
50 - 55
400
7.5 hrs
55 - 60
500
10 hrs
60 - 70
600
12 hrs
70 - 100
750
15 hrs
8 Technical data
Supply voltage
:
220 - 240 VAC
Frequency
:
50 or 60 Hz
Power consumption
:
230 W
Battery voltage, nominal
:
12 V
Battery types
:
Lead Acid, AGM, SMF, VRLA, GEL
Charging voltage, max.
:
14.8 V
Charging current, max.
:
5 A
Ambient temperature
:
-20˚C - +50˚C (-4˚F - +122˚F)
AC Cable length
:
1.8 m (6 ft)
DC Cable lenght
:
1.8 m (6 ft)
Protection
:
IP 65
Dimensions (LxWxH)
:
160 x 96 x 54 mm (6
3
/
8
x 3
3
/
4
x 2
1
/
8
inch)
Weight
:
0.85 kg (1.87 lbs)
ENGLISH