background image

1

AC220V

50~60Hz

180W

10%

200W

10%

45dB

80W

10%

80W

10%

10

dry cloth

In cold winter, the moving human body wear many clothes is easy to produce 
electrostatic, therefore please contact some conductable metal substance to release 
the electronstatic before operating the control unit.

Clean control unit with wet clean
cloth or anti-electrostatic cloth

Human body has electrostatic

Using some chemical or dry 
cloth to clean the control unit
is prohibited

5 year

Adjustable warm and cool,care health and sleeping

FUNCTION INTRODUCTION

Our machine has frequency conversion microcomputer control system, it can adjust temperature from 
20

-48

  that human body needs, the mattress inside has pipe system made of silicone material for 

liquid circulation, it makes a space between human body and mattress which not only hasten circulation 
of blood, release strain of spine and bones, but also massage muscles to direct people into sleeping and 
eliminate troubles that caused by long time lying in the hospital  after operation.

Warm in winter, cool in summer, safety and trustworth

The liquid become warm and cool by semi-condictor chip. It can adjust the temperature that people 
needs  in short time, it not only can cool down but also can replace traditional electric wire blanket, it not 
only can prevent bacteria reproduction, kill acarus,  avoid weakness of sweating, eczema, waist sore 
caused by long time lying, but also avoid the danger from magnetic-wave produced by electric wire 
blanket , completely solve the problem of nose dry, skin itch and shed, chest frowsty and dizzy feeling 
etc.

Magnetization system, environment protect

Machine magnetized system magnetize the circulating liquid, produce magnetic atmosphere, stimulate 
body point cure in magnetization, and speeding up blood circulation to hasten physical and chemical 
reaction of human body,  help to cure heart disease, hypertension, spirit enervation etc, the liquid keeps 
circulating without any magnetic declination, improve many kinds of disease, physical therapy to built 
strong body, also running periodic disinfection.

MACHINE MAIN TECH-PARAMETER.

Input voltage

Start cooling watt

Stay cooling watt

Noise

Rated frequency

Start warming watt

Stay warm watt

Life span

If keep using please clean the control unit with clean wet cloth or electrostatic-proof 
cloth, do not use chemical reagent(rot components) or dry cloth(with electrostatic) to 
clean the control unit.

Store control unit and mattress in the clean and dry place to prevent components 
from rotting or outside substances going into the control unit to affect its function.

chemical 

Summary of Contents for VT7498

Page 1: ...he real shape see your bought product Patient Warming and Cooling System User Guide Distributed and Serviced by VetTech Australia Unit 23 7 Hoyle Avenue CASTLE HILL NSW 2154 1300 339 139 www vtaus com au Please carefully read the user guide before use ...

Page 2: ...ot work with all lights on shut down the power clean and dry the operation board and restart Bad effect of warming and cooling have noise come from controlunit when running with not enough water in the tank check the water level in the tank is under warning line or not please adding water if under the warning line adjust the temperature wrongly adjust the temperature to higher or lower heat absorb...

Page 3: ...only can cool down but also can replace traditional electric wire blanket it not only can prevent bacteria reproduction kill acarus avoid weakness of sweating eczema waist sore caused by long time lying but also avoid the danger from magnetic wave produced by electric wire blanket completely solve the problem of nose dry skin itch and shed chest frowsty and dizzy feeling etc Magnetization system e...

Page 4: ... minutes then release the water with the plastic key after finish the release re fill the tank with new water then release again and again repeat twice or 3 times If mattress pad is not used for long time please release the water in the mattress with the plastic key Release water for control unit Release water for mattress CONTROL UNIT AND MATTRESS INSTALLATION INSTRUCTION A Machine appearance ins...

Page 5: ...ore unpluging the pipe Placing other substances in 15 cm around the heat releasing windows is prohibited Be sure of pluging the power plug thoroughly Do not break the electrical cable Do not change the cable and p l a c e a r o u n d t h e h e a t i n g substances do not twist bend tie with the cable it may cause fire disaster short circuit electric shock event if use a broken power plug put the c...

Page 6: ...p for at least 5 minutes on switch between warming and cooling 1 2 3 4 5 6 SET UP ON OFF 20 23 25 28 30 33 35 38 4 0 43 45 48 D Control unit remote control marks and directives 1 Control unit remote control marks singnal receiver dynamic vision stop state light warning light of water temperature bring up f c shift button temperature bring down sleep mode enter confirm timer button on off dynamic v...

Page 7: ...re and personal requirement press button to bring up temperature press to bring down the temperature press once is bring up or down 1 degree if keep pressure on is going up or down non stop to user demanded temperature and then press button Rotating button adjust type is rotate the button to user demanded temperature In hot summer no matter how cold user set the control unit as long as you press b...

Reviews: