_J
L
Wind speed range
0.5--44.7M/H, 60-3937FTIM, 0.4--38.SKNT,
1.1-20.0MIS, 0.7-72.0KMH, 1-8BF
Wind speed accuracy
±(3% of r 0.2 m/s}
Air temp. Range
•15.0-50.0
º
C
Air temp. Resolution
0.1
°
Cl°F
Air temp. accuracy
±1
º
C
Air RH% range
0.1%RH-99.9%RH
Air RH% resolution
0.1%RH
Air RH% accuracv
±
8%RH (at 25
°
c, 1o-90%RH,
Others !so/.RHI
Temp. response time
60 seconds (typical)
Air RH% response time
60 seconds (typical)
LCD update
every second
Windchill display
YES, •20.0~50.0
º
C
Dew Point temp. display
YES, -20.0-50.0
º
C
Wet bulb display
YES, -5.0-50.0
º
C
Compass display
YES, 0-360 degree
Compass accuracy
±2 degree
LCD size
16(H) x 28(W)mm
Operating temp.
-15-SO
º
c
Operating RH%
Humidity < 80%
Storage temp.
-20-SO
º
C
Storage RH%
Humidity < 90%
Dimension(mm)
140x45x25 (90
º
folded) ;
235x45x251180
°
full openedl
Weight
-90g
Battery
CR2032x1pc
Standard Package
Meter/ Battery /Manual/
Strap / Papar box
9