5.2. ZERO SETTIng
5.2.1.
Under power off condition, turn on the scale, it will stay within zero tracking range , the initial
zeroing range is K1.
5.2.2.
When the weight is within repeat zeroing range, press [ZERO] key, the weight window will display
*00000*. The manual zeroing range each time is K2 and the repeated zeroing range is K3.
5.3. TARE SETTIng
When the container or package is loaded on the platform, press [TARE] eye to enter tare mode.
The scale will display *0 * and* n .W * cursor will be light on. Press [TARE] again, it will return to
the original weighing state and * n . W * cursor will disappear. The tare may be a negative value.
The tare processes are shown in the following table:
TABLE:
Steps
Display
Meaning
load the package or container
0,10
The weight of the package or container is
0,1kg
Press [TARE] key once
0,00
Taring and the indicating cursor (light)
*n.W* (T) is on
Take away the package
-0,10
Display negative tare value
Press [TARE] key again
0,00
Clear the negative tare and the indicating
cursor (light)* n .W * (T) is off.
5.4. UnIT PRICE InPUTTIng AnD CLEARIng
5.4.1.
Directly press digit keys to input the unit price. At this time the unit price and total price of the
current goods will display in the corresponding window.
5.4.2. Two ways to clear or change unit price
• Directly clear the unit price by [C] key.
• After the previous unit price has been input for 5 seconds, press the digit keys to replace the
previous unit price value.