THIS EQUIPMENT CONTAINS NO USER SERVICEABLE COMPONENTS.

-

Servicing of the equipment must only be carried out by trained and authorized per-

sonnel.

-

Use only the AC adapter supplied with the scale. Other adapters may cause dam-

age.

Routine maintenance

-

Harsh abrasives, solvents, scouring cleaners and alkaline cleaning solutions should

not be used; especially on the display window.

-

The outside of the product may be wiped down with a clean cloth, moistened with

water containing a small amount of soap.

-

The display unit can be washed down with water.

“CE” logo here somewhere…

Installation

1. Unpack display unit and both weigh beams

2.

Set weigh beams on 

a flat and level surface. A concrete slab is recommended.

3. The beams feature adjustable feet at each end. This enables side-to-side and front-to-back

adjustment when setting up the system.

4. Install cattle chute or temporary platform

5. Install indicator in a suitable viewing area using mounting bracket

NOTES:

-

The indicator comes with a pre-installed rechargeable battery

-

The weigh beams come with pre-installed “C” cell alkaline batteries

-

Do not mix the type of batteries. Replace all batteries at the same time.

-

If the scale is not to be used for a long period of time, remove all batteries from the battery compart-

ment to avoid leakage which may cause damage to the instrument.

-

To extend the life of your digital scale, do not drop items to be weighed onto the platform or overload

the scale beyond its rated capacity. Shock-loading and overloading may damage the load cell and

void the warranty.

-

Be sure that the feet are not screwed all the way into the bar, as this will result in inaccurate

weighing

-

Never weld any installation attached to the weigh beams. Damage to the scale’s electronics

can result

-

When placing the weigh beams under a cattle squeeze chute, locate the bars at the far

ends (front & back) of the squeeze chute in order to minimize the risk of tipping when ani-

mals enter and exit the chute

-

Be sure that no equipment or objects prevent downward movement of the weigh beams.

-

Be sure that the set up does not rock from corner to corner.

Summary of Contents for WB5040-SWP

Page 1: ...MODEL WIRELESS PORTABLE SCALE User Manual Manual_WB_BT_V1 ...

Page 2: ...t NOTES The indicator comes with a pre installed rechargeable battery The weigh beams come with pre installed C cell alkaline batteries Do not mix the type of batteries Replace all batteries at the same time If the scale is not to be used for a long period of time remove all batteries from the battery compart ment to avoid leakage which may cause damage to the instrument To extend the life of your...

Page 3: ...nternal lead acid rechargeable battery Before using the indicator for the first time please charge the battery overnight The indicator s battery should operate for about 85 hours if left on continuously The display unit is configured to power down after 30 minutes of inactivity The battery can be charged while ON or OFF and the indicator can be operated while it s charg ing unless the state of cha...

Page 4: ...ead touching the grounded housing while disconnecting the other terminal Similar ly the ground should be connected last when installing a new battery The US government has classified the internal battery as hazardous waste Do not place battery into landfill An automotive store or a local waste agency may accept the batteries for recycling Contact the manufacturer for more information Operation wei...

Page 5: ...l alkaline batteries 1 Turn the bean OFF Press the RED button 2 Remove the rubber cover 3 Grasp the metal cylinder inside and carefully pull free from the housing 4 Unscrew either end cap to reveal batteries 5 Exchange the batteries be careful to note polarity 6 Replace the end cap 7 Slide the metal cylinder back into the metal housing being careful not to crimp or cut the wire Keyboard and Displa...

Page 6: ... below The display unit can show overall system battery health See the Error Messages for more in formation Function Keys Units This key toggles the indicator between lb and kg Zero Off This key sets the indicator to display zero weight provided the following conditions are met 1 The indicator is displaying Gross weight 2 The scale is not in motion 3 The scale is not in overload see error codes Pr...

Page 7: ...trying to troubleshoot setup problems 4 Remove all items from the beams and press the ZERO OFF key to zero out the displayed value 5 Press the NET GROSS key to save the zero point value The display will show EndC0 momentarily and then revert back up to F16 6 Press the ON PRINT key to progress to the F17 menu 7 While at the F 17 screen scroll down once using the ZERO OFF key to enter span calibra t...

Page 8: ...stablish a proper calibration Most commons causes include incorrect load cell wiring a mechanical obstruction or a faulty damaged load cell Error Messages Indicates that the weighing capacity of the scale has been exceeded The weight limit of the WB5040 SWP is 5000 pounds Indicates that the weight on the scale is negative Press the Zero Off key Beam 1 not found ensure that beam 1 is po wered ON an...

Page 9: ...ion MAIN COMPONENTS TS 500SS RF stainless steel digital indicator and AC adapter Two 40 weigh beams BEAM CONSTRUCTION Carbon steel tube High grade epoxy paint finish LOAD CELLS 350 ohm two per weigh beam Overload protection 200 Operating temperature 14 F to 104 F 10 C to 40 C NTEP approved Digital Indicator Specifications NEMA 4X washdown stainless steel enclosure Operating temperature 14 F to 104...

Page 10: ...m that is displaying the lower weight Check underneath the weigh beam for any obstructions Make sure that the weigh beam feet are not screwed in so far as to restrict downward movement of the weigh beam Indicator displays six small zeros Scale is overloaded Remove weight from scale Scale turns off on its own The indicator has a power conservation feature set to automatically power off the scale af...

Reviews: