background image

 

Rev. 4/18/2018 

SCTAB-FP, MANUAL 

Copyright 2018 Vestil Manufacturing Co. 

 

Page 

15

 of 

15

 

 

LIMITED WARRANTY  

 

Vestil Manufacturing Corporation (“Vestil”) warrants this product to be free of defects in material and workmanship 
during the warranty period. Our warranty obligation is

 

to provide a replacement for a defective, original part covered 

by the warranty after we receive a proper request from the Warrantee (you) for warranty service. 

 

Who may request service? 

Only a warrantee may request service. You are a warrantee if you purchased the product from Vestil or from an 
authorized distributor AND Vestil has been fully paid. 

 

Definition of “original part”? 

An original part is a part used to make the product as shipped to the Warrantee. 

 

What is a “proper request”? 

A request for warranty service is proper if Vestil receives: 1) a photocopy of the Customer Invoice that displays the 
shipping date; AND 2) a written request for warranty service including your name and phone number.  Send requests 
by one of the following methods: 

 

     US Mail   

 

 

 

               Fax   

 

 

Email 

       Vestil Manufacturing Corporation   

        (260) 665-1339 

 

    [email protected] 

       2999 North Wayne Street, PO Box 507 

               Phone                Enter “Warranty service request” 

       Angola, IN 46703  

 

 

        (260) 665-7586 

     in subject field. 

 

In the written request, list the parts believed to be defective and include the address where replacements should be 
delivered. After Vestil receives your request for warranty service, an authorized representative will contact you to 
determine whether your claim is covered by the warranty.  Before providing warranty service, Vestil will require you to 
send the entire product, or just the defective part (or parts), to its facility in Angola, IN. 

 

What is covered under the warranty?

 

The warranty covers defects in the following original, dynamic parts: motors, hydraulic pumps, electronic controllers, 
switches, and cylinders.  It also covers defects in original parts that wear under normal usage conditions (“wearing 
parts”), such as bearings, hoses, wheels, seals, brushes, and batteries. 

 

How long is the warranty period?

 

The warranty period for original dynamic components is 1 year. For wearing parts, the warranty period is 90 days. 
Both warranty periods begin on the date Vestil ships the product to the Warrantee.  If the product was purchased from 
an authorized distributor, the periods begin when the distributor ships the product.  Vestil may, at its sole discretion, 
extend a warranty period for products shipped from authorized distributors by up to 30 days to account for shipping 
time. 

 

 

If a defective part is covered by the warranty, what will Vestil do to correct the problem?

 

Vestil will provide an appropriate replacement for any 

covered

 part.  An authorized representative of Vestil will contact 

you to discuss your claim. 

 

What is not covered by the warranty? 

The Warrantee (you) are responsible for paying labor costs and freight costs to return the product to Vestil for 
warranty service.

 

 

Events that automatically void the Limited Warranty. 

 Misuse; 

  Negligent assembly, installation, operation or repair; 

  Installation/use in corrosive environments; 

  Inadequate or improper maintenance; 

  Damage sustained during shipping; 

  Collisions or other accidents that damage the product; 

  Unauthorized modifications: Do not modify the product IN ANY WAY without first receiving written authorization 

from Vestil.   

 

Do any other warranties apply to the product? 

Vestil Manufacturing Corp.

 

makes no other express warranties. All implied warranties are disclaimed to the extent 

allowed by law. Any implied warranty not disclaimed is limited in scope to the terms of this Limited Warranty. Vestil 
makes no warranty or representation that this product complies with any state or local design, performance, or safety 
code or standard. Noncompliance with any such code or standard is not a defect in material or workmanship.  
 

Summary of Contents for SCTAB-1000-2040-FP

Page 1: ...l of lading If the product is undamaged discard the packaging NOTE Responsibility for complying with laws regulations codes and non voluntary standards enforced in the location where the product is us...

Page 2: ...8 65 32 3 8 32 1 2 2 000lb 909 1 kg 337 lb 153 2 kg SCTAB 2000 4242 FP 42 3 8 32 8 64 9 16 42 3 8 32 1 2 2 000 lb 909 1 kg 358 lb 162 8 kg SCTAB 2500 2040 FP 40 3 8 31 1 8 8 63 7 16 20 3 8 20 1 2 2 50...

Page 3: ...raising or lowering the tabletop Keep clear of pinch points while the tabletop rises and lowers DO NOT reach through the legs or under the tabletop unless it is supported by the maintenance stop s DO...

Page 4: ...NOTES 1 Models with FP suffix a manual foot pump not shown in diagram raises and lowers the tabletop See Two Speed Auto Shifting Foot Pump Instruction Manual 2 Models with DC suffix an electric hydrau...

Page 5: ...NOTES 1 Models with FP suffix a manual foot pump not shown in diagram raises and lowers the tabletop See Two Speed Auto Shifting Foot Pump Instruction Manual 2 Models with DC suffix an electric hydrau...

Page 6: ...NOTES 1 Models with FP suffix a manual foot pump not shown in diagram raises and lowers the tabletop See Two Speed Auto Shifting Foot Pump Instruction Manual 2 Models with DC suffix an electric hydrau...

Page 7: ...NOTES 1 Models with FP suffix a manual foot pump not shown in diagram raises and lowers the tabletop See Two Speed Auto Shifting Foot Pump Instruction Manual 2 Models with DC suffix an electric hydrau...

Page 8: ...NOTES 1 Models with FP suffix a manual foot pump not shown in diagram raises and lowers the tabletop See Two Speed Auto Shifting Foot Pump Instruction Manual 2 Models with DC suffix an electric hydrau...

Page 9: ...NOTES 1 Models with FP suffix a manual foot pump not shown in diagram raises and lowers the tabletop See Two Speed Auto Shifting Foot Pump Instruction Manual 2 Models with DC suffix an electric hydrau...

Page 10: ...NOTES 1 Models with FP suffix a manual foot pump not shown in diagram raises and lowers the tabletop See Two Speed Auto Shifting Foot Pump Instruction Manual 2 Models with DC suffix an electric hydrau...

Page 11: ...NOTES 1 Models with FP suffix a manual foot pump not shown in diagram raises and lowers the tabletop See Two Speed Auto Shifting Foot Pump Instruction Manual 2 Models with DC suffix an electric hydrau...

Page 12: ...ssure will drop as air and oil flow from the cylinder To repressurize the system close the bleeder screw and pump the pedal just once Open the bleeder screw again to allow more trapped air to escape R...

Page 13: ...n p 13 14 Make sure all labels are in place in readable condition See Labeling diagram on p 13 Clean debris from all surfaces C Yearly Change the oil at least once a year Oil should be changed as soon...

Page 14: ...o i Increase pressure setting as necessary but NEVER more than 3 000psi j Remove relief valve and clean debris from valve seat in pump body 4 Tabletop rises during the down stroke of the pedal but des...

Page 15: ...ntrollers switches and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batteries How long is th...

Reviews: