Dimensions and other product specifications appear in the following diagrams and table. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNAL WORDS   

This manual classifies personal injury risks and situations that might cause property damage with signal words. 

Signal words indicate the seriousness of injuries that might result if a particular act does, or does not, occur. 

 

  

 

Identifies a hazardous situation which, if not avoided, COULD result in DEATH or 

SERIOUS INJURY. 

 

 

Identifies practices likely to result in product/property damage, such as operation that might 

damage the product. 

 

 

 

SAFETY INSTRUCTIONS 

Vestil  strives  to identify all hazards associated with the use of our products. However, material handling is 

dangerous and no manual can address every risk. The most effective way to avoid injury is for the end-user to 

exercise sound judgment whenever using this product.

 

 Improper or careless operation might result in serious personal injuries or death. 

  Read and understand the entire manual before installing, using or servicing the product

.

 

  Read the manual to refresh your understanding of proper use and maintenance procedures. 

  Do not operate the crusher with the loading door open. 

  Do not operate the machine if the emergency stop switch does not function properly. 

  Do not stand in front of the door during operation. 

  Keep clear of all moving parts during operation. 

  High pressure oil easily punctures skin which can cause injury such as gangrene. If a hose or coupling leaks, 

repair the leak before operating the crusher. 

  Do not use the crusher if it is damaged or makes unusual noises during operation. 

  Do not change the pressure relief valve setting! In particular, do not 

increase

 the setting. 

  Do not clean out the drum crusher unless power is disconnected. 

  Do not attempt to crush smooth-walled pails with this machine. Pails must be ribbed to crush properly. Dent the 

side of the pail in a few places before loading it into the crusher. 

  Only use this unit to crush 

empty

 pails. Do not attempt to crush filled pails.  

  Do not use brake fluids or jack oils in the hydraulic system. Only use AW-32 hydraulic oil or its equal. 

  Do not modify the product in any way. Modifications might make the lifter unsafe to use and automatically void the 

Limited Warranty

. See p. 10. 

  DO NOT use this device unless every label is in place and easily readable. See 

Labeling Diagram

 on. p. 9. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                     

 

Dimensions: 

Overall width   

= 27” 

Usable inside width 

= 14

1

/

2

” 

Overall length   

= 22

3

/

16

” 

Usable inside length 

= 13

7

/

8

” 

Overall height   

= 64

9

/

16

” 

Usable inside height 

= 19

1

/

4

” 

Crushing force 

= 10,000 lb. 

Hydraulic system 

pressure 

= 3,000 PSI 

Max. pail size 

= 5 gal.  

Motor voltage 

= 115VAC 

Net weight (approx..)  = 191 lb. 

18” piston stroke crushes pails to 

2in. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HPC-405

Page 1: ...labels and accessories call our Technical Service and Parts Department at 260 665 7586 The Department can also be contacted online at https www vestil com page parts request php Electronic Copies of Instruction Manuals Additional copies of this instruction manual may be downloaded from https www vestil com page manuals php A Vestil Manufacturing Corp 2999 North Wayne Street P O Box 507 Angola IN 4...

Page 2: ... the machine if the emergency stop switch does not function properly Do not stand in front of the door during operation Keep clear of all moving parts during operation High pressure oil easily punctures skin which can cause injury such as gangrene If a hose or coupling leaks repair the leak before operating the crusher Do not use the crusher if it is damaged or makes unusual noises during operatio...

Page 3: ...ght 2021 Vestil Manufacturing Co Page 3 of 11 ELECTRICAL CIRCUIT DIAGRAM 115VAC SINGLE PHASE 22 124 028 REV B NOTES Indicates wire and or components not included with unit All components shown with unit in normal starting position i e ram fully raised and cabinet door open ...

Page 4: ...t 2021 Vestil Manufacturing Co Page 4 of 11 ELECTRICAL CIRCUIT DIAGRAM 208 230VAC SINGLE PHASE 22 124 029 REV B NOTES Indicates wire and or components not included with unit All components shown with unit in normal starting position i e ram fully raised and cabinet door open ...

Page 5: ...Copyright 2021 Vestil Manufacturing Co Page 5 of 11 ELECTRICAL CIRCUIT DIAGRAM 3 PHASE 22 124 030 REV B NOTES Indicates wire and or components not included with unit All components shown with unit in normal starting position i e ram fully raised and cabinet door open ...

Page 6: ... BOLT GRADE A ZINC PLATED 3 8 16 X 1 2 18 33008 FLAT WASHER LOW CARBON USS ZINC PLATED 3 8 6 7 37024 NYLON INSERT LOCK NUT GRADE 2 ZINC FINISH 3 8 16 2 19 11107 HEX BOLT GRADE A ZINC FINISH 3 8 16 x 1 1 4 4 8 22 525 003 WELDMENT HANDLE TIE BAR 1 20 22 514 045 WELDMENT DOOR 1 9 99 021 949 CYLINDER HYDRAULIC Ø2 1 2 x 18 PISTON STYLE FLANGE MOUNT 1 21 11053 Ø 5 16 18 x 3 4 LG HHCS 2 Z PLATED GRADE A ...

Page 7: ...hat point Pressing the START button again begins a new cycle Hold the button for a few seconds to latch the circuit wait until you hear the motor turn on and begin the cycle When the crusher is in home position and the cycle start button is pressed the cylinder pushes the platen down onto or into if operating in COMPACT mode the pail In order to achieve a short cycle time both sections of the pump...

Page 8: ...CUIT 1 1 2 99 153 052 VALVE HYDRAULIC 4 WAY 3 POS MOTOR CENTER VC08 3 1 1 3 99 153 011 VALVE CHECK NOSE IN SIDE OUT VC08 2 1 4 99 153 006 VALVE PRESSURE RELIEF 210 BAR 1 1 5 99 153 110 VALVE SEQUENCE HYDRAULIC VC08 1 1 6 99 034 008 ACCESSORIES 24VAC COIL W DIN CONNECTOR 2 2 99 021 949 CYLINDER HYDRAULIC Ø2 1 2 x18 FLANGE MOUNT 1 3 01 135 050 MOTOR 3 4HP 1PH 1800RPM 56F 1 4 01 143 906 002 PUMP VANE...

Page 9: ...TION Only use the unit if it is in satisfactory condition If an inspection reveals any changes from satisfactory condition repair restore the unit to satisfactory conditin before returning it to service Only use manufacturer approved replacement parts DON T GUESS Contact TECHNICAL SERVICE if you have questions that are not addressed in these instructions or if you are uncertain how to address an i...

Page 10: ...ndition Replace all labels that are damaged missing or not easily readable e g faded Order replacement labels by contacting the Replacement Parts Department online at http www vestilmfg com parts_info htm Alternatively you may request replacement parts and or service by calling 260 665 7586 and asking the operator to connect you to the Parts Department A B B C E F D A Label 206 by plug C Label 248...

Page 11: ...ydraulic pumps motor controllers and cylinders It also covers defects in original parts that wear under normal usage conditions wearing parts such as bearings hoses wheels seals brushes and batteries How long is the warranty period The warranty period for original dynamic components is 1 year For wearing parts the warranty period is 90 days Both warranty periods begin on the date Vestil ships the ...

Reviews: