Version V2C22021
Vesticam
™
User Manual
Page | 26
APPENDIX 1: Effective Cleaning of Vesticam IR Video Goggles, References
1.
Instilling a culture of cleaning: Effectiveness of decontamination
practices on non-disposable sphygmomanometer cuffs
Zimmerman P, Browne M, Rowland D. Journal of Infection Prevention, Volume: 19 issue: 6, page(s): 294-299
This recent study from Australia tested whether disinfection of blood pressure cuffs using disinfectant wipes was an
effective (and cost saving) option. A sample of 54 non-disposable sphygmomanometer cuffs were collected from a
rural emergency department and tested for bacterial contamination before and after decontamination using Clinell
Universal Wipes. Levels of contamination were significantly lower following decontamination with the wipes; 29% of
the cuffs had no growth before decontamination compared with 98% after decontamination. The authors concluded
that using wipes to decontaminate non-disposable cuffs would be clinically effective, environmentally friendly, and
cost-saving compared with using disposable cuffs.
“
Decontamination of non-disposable sphygmomanometer cuffs decreases microbial load and risk of HAI, providing
evidence to negate arguments for disposable cuffs while being environmentally sensitive and supportive of a culture
of patient safety and infection control
”.
2.
Contamination of blood pressure cuffs by methicillin-resistant staphylococcus aureus and preventive
measures.
Matsuo M, Oie S, Furukawa H.
Ir J Med Sci.
2013;182(4):707-709.
This study sampled pressure cuffs in wards and outpatient clinics at an acute-care hospital in Japan. The cuffs were
sampled on the inside (skin-contact side) using gauzes. Of the 30 cuffs sampled, 11 (31.4%) were contaminated with
MRSA! The team also evaluated two different methods of disinfection: an outsourced washing process and wiping
with 80% ethanol. No cuffs were found to be contaminated following either disinfection process.
Only a small number of cuffs were included in the disi
nfection study, and they weren’t sampled before and after
treatment, but these findings reinforce that blood pressure cuff disinfection is an option.
3.
Effectiveness and feasibility of using a physical barrier device in reducing rates of microbial
contamination of sphygmomanometer cuffs
Nitin Bhanot et al., Journal of Infection Prevention, 2011
“
Sphygmomanometers are frequently contaminated with bacteria and are implicated in the transmission of
microbes. A pilot study was conducted to determine the effectiveness and feasibility of using a physical barrier
device in reducing rates of microbial contamination of sphygmomanometer cuffs. A disposable plastic device acting
as a physical barrier may not reduce surface contamination of sphygmomanometer cuffs.
”
4.
Infection control guidelines for optometrists 2016
First published:09 June 2017
Downloaded 27/3/2020
https://onlinelibrary.wiley.com/doi/full/10.1111/cxo.12544
Infection control guidelines for Optometrists 2016 recommends the use of 70% alcohol swab and air drying in non-
critical reusable equipment, if infection is suspected.
APPENDIX 2: Vesticam Binocular Reference Manual
Please contact
to request this as a separate document.