Prapared by Customer Technical Supoort Department in Vestel Washing Machine Plant – Manisa – Turkey
Page 31
9.6. Electronic Pressure Sensor (EPS)*
Electromagnetic field occurs due to movement
of pressurized membrane. The spring moves
vertically by nucleus due to electromagnetic
field. The water level is regulated according to
the frequency changes of the spring by
electronic card.
EPS
Testing component
Press the door lock with using screw driver.
Select a program and press the start button.
Bring porgram knob to position 1 (Cotton 90°C
program)
Wait for water intake step to finish. You can
recognize it by listening the water sound or
slightly opening and observing detergent drawer
As soon as water intake is over turn program
knob to position 0 (Off position)
Check water level from door glass. The water
level should be just below door glass as seen in
the picture below: (There is a %10 tolerance
with this level)