Prapared by Customer Technical Supoort Department in Vestel Washing Machine Plant – Manisa – Turkey
Page 10
6. Service Mode
6.1. Service Autotest
5.1.1. Service Autotest Steps
1. Open SI by pressing SW4 for 5 seconds.
If you turn knob position to other program between 1st to
3
rd
it will skip current test and start the selected one. It is
recommended not to skip any steps for a detailed
checkup. Unlike autotest, service autotest starts next test
step manually by rotating program selection knob.
Step1:
There will be a certain amount of water intake and then
washer heater is activated for 8 minutes. Washer NTC
values are checked in this period. In case of a washer
heater/NTC failure, it pops up E05 error displaying “E05”
on SW3.
In case of no failure at the end of heating step, “Please
change selector” will be displayed. You can turn program
knob to 2
nd
position to continue with step2.
*During this step if EPS detects high water level, overflow
algorithm is applied and E04 is released.
*If user changes the selector position, machine will do
what is defined for the new selected position.
Step2:
Drain pump is activated; in case of a pump failure it pops
up E03 error.
At the end of pump activation, “Please
change selector” will be displayed. You can turn program
knob to 3
rd
position to continue with step3.
Step3:
Rapid 12’*(15’ for non-TJ models) program algorithms is
run testing all washing components, the only difference is
error codes are displayed on SW3 which normally are not
displayed to end user.
If case of no error service autotest ends and "End" is
displayed.
3.
2. Press button below “SAU” indication which stands
for
Service Autotest.
3. When autotest is finished, END screen is
visualized.
Step1
Step 2
Step 3
PR Position:
Program 1
PR Position:
Program 2
PR Position:
Program 3
HEATER ON
PUMP ON
TEST PROGRAM
ON (Rapid 12’*)
Comments :
When
entering in
service test,
door will be
locked.
Test is over
Door will be
unlocked,
machine will go
to END state.