Door Switch : 
 

From the Electronical Card: 
 

   on the connectors CN2.9 – CN2.2   ( Door is close ) 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Above sketch show the connectors of the door switch on the electronical card.  
 
 
 

 
From the component: 
 
 
 

 

 
 
Probes of the tester should be applied on to the related connectors as shown on the pictures. 
 
 
 

 

ELECTRONC CARD 

     CONNECTOR 

PU

RPL

E

  

0

,5

 

B

R

O

W

N

  

0

,5

 

Summary of Contents for ANGELO FNAC11

Page 1: ... 1 SEMI INTEGRATED FULLY INTEGRATED FREE STANDING DISHWASHERS TRAINING DOCUMENT ...

Page 2: ...es have different panel versions Fully Integrated models have built in adjustment mechanism and hinge spring adjustment mechanism ANGELO SERIES ANGELO classified FNAC11 FNPC12 FNAC13 FNAC21 FNAC31 FNAC41 They are produced 6 different versions PETRA SERIES PETRA classified FNPC11 FNPC12 FNPC13 FNPC21 They are produced 4 different versions ...

Page 3: ...TED SERIES Semı Integrated classified SNSC11 SNSC13 SNSC31 SNSC41 They are produced 4 different versions FULLY INTEGRATED SERIES Fully Integrated classified INRD13 INRD21 INRD41 They are produced 3 different versions ...

Page 4: ...e 70 C Prewash Hygiene 60 C Yes Quick program 30 40 C Yes Yes Yes Yes Delicate program 40 C Yes Super Program 55 60 C Yes Functions Tablet detergent Yes Prewash Yes Yes Yes 1 2 Load Yes Yes Indicators Rinse Aid Indicator Yes Yes Yes Salt Indicator Yes Yes Yes Fallowing Programme Indicator Yes Yes Yes Yes Yes Yes Set the Time Yes Yes Yes Remaining Time Indicator Yes Child Lock Yes Yes Yes Baskets T...

Page 5: ...7 2 1 55 FNAC21 FNPC21 INRD21 Program Time min Water Consumption lt Energy Consumption kWh Prewash 15 4 5 0 02 Quick 40 C 30 12 4 0 68 Economic 50 C 150 15 7 1 05 Normal 55 C 95 16 5 1 1 Intensive 65 C 110 17 2 1 55 FNAC21 FNPC21 INRD21 With Prewash Option Selected Program Time min Water Consumption lt Energy Consumption kWh Quick 40 C Prewash 45 16 9 0 7 Economic 50 C Prewash 165 20 2 1 07 Normal...

Page 6: ...onomic 50 C 170 13 5 1 05 Super 55 min 60 C 55 11 0 93 Hygiene 60 C 119 15 1 55 Extra Hygiene 161 22 7 1 75 FNAC41 FNPC41 SNSC41 INRD41 With Half Load Option Selected Program Time min Water Consumption lt Energy Consumption kWh Prewash 15 4 2 0 02 Automatic Delicate 30 50 C 62 81 9 9 13 7 0 79 0 94 Automatic Normal 50 60 C 85 107 10 5 14 3 1 1 1 28 Automatic Intensive 60 70 C 113 163 11 9 19 9 1 2...

Page 7: ... 7 NAME PLATE ...

Page 8: ...of the tap water For this reason your machine is equipped with a system that reduces the hardness in mains water supply The washing effectiveness will increase when the system is correctly set To make the system setting use the testing strip if it is available and find the hardness of the mains water supply ...

Page 9: ...sing the Power On Off button c Keep Start Pause button pressed until program monitor lights are on and off d After the lights have flashed release the Start Pause button Your machine displays the latest entered water hardness setting You can adjust the levels by pressing Start Pause button according to the table of Water Hardness Level Settings You can adjust tle levels by pressing and buttons pla...

Page 10: ...Level Indicators Water Hardness Level German Hardness dH French Hardness dF British Hardness dE HARDNESS LEVEL INDICATORS 1 0 5 0 9 0 6 2 6 11 10 20 7 14 3 12 17 21 30 15 21 4 18 22 31 40 22 28 5 23 31 41 55 29 39 6 32 50 56 90 40 63 ...

Page 11: ...vel Indicators Water Hardness Level German Hardness dH French Hardness dF British Hardness dE HARDNESS LEVEL INDICATORS 1 0 5 0 9 0 6 2 6 11 10 20 7 14 3 12 17 21 30 15 21 4 18 22 31 40 22 28 5 23 31 41 55 29 39 6 32 50 56 90 40 63 ...

Page 12: ...l Indicators Water Hardness Level German Hardness dH French Hardness dF British Hardness dE HARDNESS LEVEL INDICATORS 1 0 5 0 9 0 6 2 6 11 10 20 7 14 3 12 17 21 30 15 21 4 18 22 31 40 22 28 5 23 31 41 55 29 39 6 32 50 56 90 40 63 ...

Page 13: ...elector button pressed until P1 P2 P3 P4 End lights are on andoff d After the P1 P2 P3 P4 End have flashed release the Program selector button Your machine displays the latest entered water hardness setting e You can adjust the levels by pressing Program selector button according to the table of Water Hardness Level Settings f After adjusting the water hardness level press on off button to save se...

Page 14: ...ater Hardness Level German Hardness dH French Hardness dF British Hardness dE HARDNESS LEVEL INDICATORS 1 0 5 0 9 0 6 2 6 11 10 20 7 14 3 12 17 21 30 15 21 4 18 22 31 40 22 28 5 23 31 41 55 29 39 6 32 50 56 90 40 63 ...

Page 15: ...til P1 P2 P3 P4 P5 3h 6h 9h End lights are on and off d After the P1 P2 P3 P4 P5 3h 6h 9h End have flashed release the Program selector button Your machine displays the latest entered water hardness setting e You can adjust the levels by pressing Program selector button according to the table of Water Hardness Level Settings f After adjusting the water hardness level press on off button to save se...

Page 16: ...ter Hardness Level German Hardness dH French Hardness dF British Hardness dE HARDNESS LEVEL INDICATORS 1 0 5 0 9 0 6 2 6 11 10 20 7 14 3 12 17 21 30 15 21 4 18 22 31 40 22 28 5 23 31 41 55 29 39 6 32 50 56 90 40 63 ...

Page 17: ... button pressed until SL expression is on and off d After the SL expression have flashed release the Program selector button Your machine displays the latest entered water hardness setting e You can adjust the levels by pressing Program selector button according to the table of Water Hardness Level Settings f After adjusting the water hardness level press on off button to save settings in memory ...

Page 18: ...ter Hardness Level German Hardness dH French Hardness dF British Hardness dE HARDNESS LEVEL INDICATORS 1 0 5 0 9 0 6 2 6 11 10 20 7 14 3 12 17 21 30 15 21 4 18 22 31 40 22 28 5 23 31 41 55 29 39 6 32 50 56 90 40 63 ...

Page 19: ...41 model press and buttons on Remaining time indicator simultaneously for 4 seconds At this time CL appears for 2 seconds on remaining time indicator Inactivate Child Lock Press Start Pause and Delay buttons simultaneously for 4 seconds When activated 3h washing lamp flashes twice In C41 model press and buttons again simultaneously for 4 seconds CL will blink for 2 times ...

Page 20: ...D21 When you press delay button 3h lamp flashes If you continue pressing delay button 6h 9h lamb will flash If you press delay button again after 9h lamb flashed delay will reset You may select the delay time after selecting the programme IND 41 When you press delay button 1h appears on program display If you continue pressing delay button 1h 2h 19h lamb will flash respectively for each pressing Y...

Page 21: ...emi Integrated Models a Press Start Pause button b Turn the Program Selection Button to Reset c Press once the Start Pause button The machine will drain the water in it for nearly 30 sec When the end lamb is on the program will have been cancelled ...

Page 22: ...The machine will drain the water in it for nearly 30 sec When the program is cancelled tha machine signals and end lamb is on IND41 a If you want to reset the program while your machine is working open the door and press program button along 3sec until 1 appears on dispaly b After closing the door draining will start The machine will drain the water in it for nearly 30 sec When the program is canc...

Page 23: ...dels a Press Start Pause button b After the program stops select your desired program via the Program selection button c Start the program you have newly selected by pressing again Start Pause button The new program started will resume the course of the old program ...

Page 24: ...our desired program via the Program selection button b The new program started will resume the course of the old program IND41 Model a Open the door and select your desired program via the Program selection button b The new program started will resume the course of the old program ...

Page 25: ...not in operation Keep the start pause button pressed down meanwhile energise the machine by pressing the on off button b Keep the start pause button pressed until the flow indicators are on and off It takes 5sec c After the flow indicators are on and off move the programme selector knob to the reset position Keep the start pause button pressed again until the flow indicators are on and off After f...

Page 26: ...r button pressed until all indicators are on and off for the second time d After all the lights have flashed release the Program selector button The machine shows the last error then starts to sevice programme e End of the programme the end lamb is on If the machine comes to error position the lambs showed failure codes are on and the machine shows the first failure code on service programme f Pre...

Page 27: ...n pressed until SP appears on display d After all the lights have flashed release the Program selector button The machine shows the last error then starts to sevice programme e End of the service programme the end lamb is on If the machine comes to error position the lambs showed failure codes are on and the machine shows the first failure code on service programme f Press on off button to close t...

Page 28: ...mp 1 min 10sec Circulation pump detergant dispenser 5 Wash pump Heating 5 min Heater Casing pressure switch NTC diverter positions 6 Regeneration 1 min Regeneration valve 7 Drain 20sec Drain Pump 8 End led highlight Note The values declared above are the values obtained under laboratory conditions according to the relevant standards These values can change depending on conditions of product s use ...

Page 29: ...er inlet valve filter can be clogged 5 Water inlet valve can be out of order 6 There can be a problem with the cable connection of water inlet valve 7 Floater switch can be out of order or have a problem with the cable connection 8 Pressure switch of the heater casing group can have a mechanical or cable connection problem 9 Circulation pump can be out of order or have a problem with the cable con...

Page 30: ...connection of the drain pump 5 Pressure switch of the heater casing group can have a mechanical or cable connection problem 4 Intended water temperature could not be reached faulty heater and or heater sensor Possible problems 1 NTC can be out of order 2 NTC cable connection can be faulty NTC can be short or open circuit 3 Thermal protection can be out of order 4 Heater can be out of order or cabl...

Page 31: ...on 3 Drain pump and pessure switch can be out of order at the same time 4 Electronic card can be out of order 6 Electronic card parameter faulty Possible problems 1 By the immediate and continuous voltage decreases software variants can not be kept in the memory of electronic card 2 The program contiues when you restart it You should warn the user about controlling the network voltage ...

Page 32: ... order 2 Cable connection of flowmeter can be faulty 3 Electronic card can be out of order 8 Door is open Possible problems 1 Door lock mechanism can be out of order 2 There can be a problem with the cable connection of door lock 3 Electronic card can be out of order ...

Page 33: ...er inlet valve filter can be clogged 5 Water inlet valve can be out of order 6 There can be a problem with the cable connection of water inlet valve 7 Floater switch can be out of order or have a problem with the cable connection 8 Pressure switch of the heater casing group can have a mechanical or cable connection problem 9 Circulation pump can be out of order or have a problem with the cable con...

Page 34: ... order 4 There can be a problem with cable connection of the drain pump 5 Pressure switch of the heater casing group can have a mechanical or cable connection problem 4 Heater Error Inadequate heat Possible problems 1 Heater can be out of order 2 There can be a problem with cable connection of the heater 3 Thermal protection can be out of order 4 Electronic card can be out of order ...

Page 35: ...nnection 2 Electronic card can be out of order 6 Alarm is active against water leakage Possible problems 1 There can be a water leakage from the tub 2 Floater switch can be out of order or have a problem with the cable connection 3 Drain pump and pessure switch can be out of order at the same time 4 Electronic card can be out of order ...

Page 36: ...on problem Possible problems 1 There can be a water leakage to diverter contacts and diverter electric contacts can have open circuit 2 There can be a problem with cable connection of the diverter 3 Electronic card can be out of order 9 NTC faulty Possible problems 1 NTC can be out of order 2 NTC cable connection can be faulty NTC can be short or open circuit 3 Electronic card can be out of order ...

Page 37: ...n the user about controlling the network voltage 11 Electronic card water hardness faulty Possible problems 1 Water Hardness is not adjusted or Water Hardness adjustment can not be kept in the elctronic card memory 2 Water Hardness should be adjusted by controlling the supply water 12 Faulty Flowmeter Possible problems 1 Flowmeter can be out of order 2 Cable connection of flowmeter can be faulty 3...

Page 38: ...t of order 2 There can be some soil around the turbidity sensor 3 Electronic card can be out of order 14 Door is open Possible problems 1 Door lock mechanism can be out of order 2 There can be a problem with the cable connection of door lock 3 Electronic card can be out of order ...

Page 39: ...ve filter can be clogged 5 Water inlet valve can be out of order 6 There can be a problem with the cable connection of water inlet valve 7 Floater switch can be out of order or have a problem with the cable connection 8 Pressure switch of the heater casing group can have a mechanical or cable connection problem 9 Circulation pump can be out of order or have a problem with the cable connection 2 Er...

Page 40: ... order 4 There can be a problem with cable connection of the drain pump 5 Pressure switch of the heater casing group can have a mechanical or cable connection problem 4 Heater Error Inadequate heat Possible problems 1 Heater can be out of order 2 There can be a problem with cable connection of the heater 3 Thermal protection can be out of order 4 Electronic card can be out of order ...

Page 41: ...nnection 2 Electronic card can be out of order 6 Alarm is active against water leakage Possible problems 1 There can be a water leakage from the tub 2 Floater switch can be out of order or have a problem with the cable connection 3 Drain pump and pessure switch can be out of order at the same time 4 Electronic card can be out of order ...

Page 42: ...lems 1 NTC can be out of order 2 NTC cable connection can be faulty NTC can be short or open circuit 3 Electronic card can be out of order 9 Electronic card parameter faulty Possible problems 1 By the immediate and continuous voltage decreases software variants can not be kept in the memory of electronic card 2 The program contiues when you restart it You should warn the user about controlling the...

Page 43: ... 43 10 Faulty Flowmeter Possible problems 1 Flowmeter can be out of order 2 Cable connection of flowmeter can be faulty 3 Electronic card can be out of order ...

Page 44: ...ve filter can be clogged 5 Water inlet valve can be out of order 6 There can be a problem with the cable connection of water inlet valve 7 Floater switch can be out of order or have a problem with the cable connection 8 Pressure switch of the heater casing group can have a mechanical or cable connection problem 9 Circulation pump can be out of order or have a problem with the cable connection 2 Er...

Page 45: ... of the heater casing group can have a mechanical or cable connection problem 4 Heater Error Inadequate heat Possible problems 1 Heater can be out of order 2 There can be a problem with cable connection of the heater 3 Thermal protection can be out of order 4 Electronic card can be out of order 5 Alarm is active against water overflow Possible problems 1 Floater switch can be out of order or have ...

Page 46: ...n be out of order at the same time 4 Electronic card can be out of order 7 Exceed heating problem temp of water inside the machine is too high Possible problems 1 Water inside the machine is 77 C NTC can be out of order 2 Electronic card can be out of order 8 NTC faulty Possible problems 1 NTC can be out of order 2 NTC cable connection can be faulty NTC can be short or open circuit 3 Electronic ca...

Page 47: ... variants can not be kept in the memory of electronic card 2 The program contiues when you restart it You should warn the user about controlling the network voltage 10 Faulty Flowmeter Possible problems 1 Flowmeter can be out of order 2 Cable connection of flowmeter can be faulty 3 Electronic card can be out of order ...

Page 48: ...ve filter can be clogged 5 Water inlet valve can be out of order 6 There can be a problem with the cable connection of water inlet valve 7 Floater switch can be out of order or have a problem with the cable connection 8 Pressure switch of the heater casing group can have a mechanical or cable connection problem 9 Circulation pump can be out of order or have a problem with the cable connection 2 Er...

Page 49: ... order 4 There can be a problem with cable connection of the drain pump 5 Pressure switch of the heater casing group can have a mechanical or cable connection problem 4 Heater Error Inadequate heat Possible problems 1 Heater can be out of order 2 There can be a problem with cable connection of the heater 3 Thermal protection can be out of order 4 Electronic card can be out of order ...

Page 50: ...nnection 2 Electronic card can be out of order 6 Alarm is active against water leakage Possible problems 1 There can be a water leakage from the tub 2 Floater switch can be out of order or have a problem with the cable connection 3 Drain pump and pessure switch can be out of order at the same time 4 Electronic card can be out of order ...

Page 51: ...sition problem Possible problems 1 There can be a water leakage to diverter contacts and diverter electric contacts can have open circuit 2 There can be a problem with cable connection of the diverter 3 Electronic card can be out of order 9 NTC faulty Possible problems 1 NTC can be out of order 2 NTC cable connection can be faulty NTC can be short or open circuit 3 Electronic card can be out of or...

Page 52: ...n the user about controlling the network voltage 11 Electronic card water hardness faulty Possible problems 1 Water Hardness is not adjusted or Water Hardness adjustment can not be kept in the elctronic card memory 2 Water Hardness should be adjusted by controlling the supply water 12 Faulty Flowmeter Possible problems 1 Flowmeter can be out of order 2 Cable connection of flowmeter can be faulty 3...

Page 53: ... 53 13 Faulty turbidity sensor Possible problems 1 Turbidity sensor can be out of order 2 There can be some soil around the turbidity sensor 3 Electronic card can be out of order ...

Page 54: ...y at the end of the programme Models haved half load option When both lamps are not flashed it means the machine will continue normal operation When the lamps are not flashing does not mean spray arms are not rotating The customers should be informed about looking at instruction manual at first when they face to failure After installing the machine to a suitable place run it unloaded for the first...

Page 55: ...sm Built in feet adjustment mechanism You can easily adjust the machine backward feet through built in adjustment mechanism Built in adjustment mechanism consists 4 main parts Built in adjustment mechanism Built in warm gear Built in height mechanism axle Built in adjustment mec front cover Built in hinge spring adjustment mechanism Adjust the machine door by using screwdriver as you have seen in ...

Page 56: ...TER DRAIN PUMP CN2 2 CN2 4 143 Ω 7 WATER INLET VALVE CN2 6 CN 2 9 3750 Ω 10 20Cº REGENERATION VALVE CN2 10 CN2 7 4130 Ω 10 25 Cº SALT SENSOR CN5 1 CN5 2 0 Ω NO SALT Ω THERE IS SALT MEASURE JUST ON THE ELECTRONIC CARD HEATER 26 19 15 Ω MEASURE JUST ON THE COMPONENT DETERGENT DISPENSER 1660 Ω 10 25 C º MEASURE JUST ON THE COMPONENT CIRCULATION PUMP CN2 3 CN2 9 95 7 Ω 126 7 Ω Primary winding Secondar...

Page 57: ... of the tester should be applied on to the related connectors of the electronical card control the values according to the resistance value table picture b Free standing and semi ıntegrated electronic card Fully Integrated electronic card Free standing and semi ıntegrated display card Fully Integrated display card ...

Page 58: ...inding must be 95 Ω on the connectors CN2 3 CN2 9 Above sketch show the connectors of the washing pump on the electronical card Probes of the tester should be applied on to the related connectors From the component Probes of the tester should be applied on to the related connectors as shown on the pictures Measurement of the primary windings of the washing pump Measurement of the secondary winding...

Page 59: ... CN2 2 CN2 4 Above sketch show the connectors of the drain pump on the electronical card Probes of the tester should be applied on to the related connectors From the component Probes of the tester should be applied on to the related connectors as shown on the pictures ...

Page 60: ...ow the connectors of the water inlet valve on the electronical card Probes of the tester should be applied on to the related connectors From the component Probes of the tester should be applied on to the related connectors as shown on the pictures ELECTRONIC CARD CONNECTOR BLUE 0 5 CONNECTOR BLUE 0 5 PURPLE 0 5 ...

Page 61: ...5 Ω Probes of the tester should be applied on to the related connectors as shown on the pictures Detergent Dispenser It can t be measured from the electronical card 1660 10 Ω 25 C º From the component Probes of the tester should be applied on to the related connectors as shown on the pictures ...

Page 62: ...the component Probes of the tester should be applied on to the related connectors as shown on the pictures CONNECTOR ELECTRONIC CARD Above sketch show the connectors of the regeneration valve on the electronical card Probes of the tester should be applied on to the related connectors ORANGE 0 5 PINK 0 5 ...

Page 63: ...ty Above sketch show the connectors of the pressure switch on the electronical card Probes of the tester should be applied on to the related connectors From the component Probes of the tester should be applied on to the related connectors as shown on the pictures ELECTRONIC CARD CONNECTOR ORANGE 0 5 BROWN 0 5 ...

Page 64: ...N 3 2 90 488Ω 8 5 Above sketch show the connectors of NTC sensor on the electronical card Probes of the tester should be applied on to the related connectors From the component Probes of the tester should be applied on to the related connectors as shown on the pictures ELECTRONIC CARD CONNECTOR BLACK 0 35 RED 0 35 ...

Page 65: ...ors CN6 1 CN 2 9 Sketch above show the connectors of the diverter on the electronical card Probes of the tester should be applied on to the related connectors From the component Probes of the tester should be applied on to the related connectors as shown on the pictures ...

Page 66: ...ctronical card Probes of the tester should be applied on to the related connectors From the component Salt sensor can also be measured from the water softener when the salt sensor assemblied on the water softener Probes of the tester should be applied on to the related connectors as shown on the pictures ELECTRONIC CARD CONNECTOR BLACK 0 35 RED 0 35 ...

Page 67: ...MİCROSWITCH IS ACTIVE WATER Position 1 You can check the floater by controlling the specified value intervals Position 2 If failure code is occured related with the floater within control the above values you can figure out whether leakage occurs or not ELECTRONICAL CARD ELECTRONIC CARD BLACK 0 5 WHITE 0 5 WHITE 0 5 RED 0 5 ...

Page 68: ...rs CN2 9 CN2 2 Door is close Above sketch show the connectors of the door switch on the electronical card From the component Probes of the tester should be applied on to the related connectors as shown on the pictures ELECTRONC CARD CONNECTOR PURPLE 0 5 BROWN 0 5 ...

Page 69: ...l Card 238 6 Ω 5 on the connectors CN 6 2 CN 2 9 Above sketch shows the connectors of the fan motor on tke electronical card From the component Probes of the tester should be applied on to the related connectors as shown on the pictures ...

Page 70: ... CN 5 2 CN 5 3 Ω There is rinse aid Above sketch shows the connectors of the rinse aid sensor on tke electronical card From the component Probes of the tester should be applied on to the related connectors as shown on the pictures CONNECTOR ELECTRONIC CARD WHITE 0 35 BLACK 0 35 ...

Page 71: ... 71 On Off Button It can t be measured from the electronical card From the component 0 Ω When the button is pressed ...

Page 72: ...FORMATIONS Machine does not work 1 Check the plug is connected or not 2 Control supply voltage 3 Control the supply cord 4 Control cable connections 5 Control the connector connections of pcb card 6 Control the pcb card ...

Page 73: ...er inlet valve 4 Be sure that the water inlet valve filter are not clogged if be clogged clean the filter 5 Check the connection of the water inlet valve and water inlet hose 6 Control the water inlet valve filter if it is clogged clean the filter 7 After these operations failure still continue please change the water inlet valve Also filter inside should be cleaned Filtre should be cleaned ...

Page 74: ...enser 2 Customer can load the lower basket with big plates and these plates can block the opening of the dispenser cover Below pictures show the position of dispenser cover Closed Position Opened Position Energise the connectors externally and control the working of the dispenser Also you can control the mechanical parts of the dispenser during energising ...

Page 75: ...s position and the water may not be enough to melt the tablet detergant When the customers see the dissolved detergant at the end of the programme they may complain that machine does not melt the detergant Big plates can block the opening of the dispenser cover ...

Page 76: ...nt FNPC11 FNPC12 FNPC13 haven t got any rinse aid indicator Control the rinse aid by using the rinse aid level indicator There isn t any rinse aid There is rinse aid FNPC21 FNPC31 and FNAC41 have rinse aid indicator on the control panel There isn t any rinse aid There is rinse aid 4 There can be mechanical or electrical problem with the detergant dispenser 5 There can be a problem on the PCB card ...

Page 77: ...ay arms can be blocked by the cutleries The customers might control the rotating of spray arms before starting the machine 4 There is a mechanical or electrical problem on the detergant dispenser If it is please change the detergant dispenser 5 There can be a problem with the heater casing Check the electrical values If there is a problem change the heater casing 6 There can be a problem with the ...

Page 78: ... objects by the power of the water 2 Substances that might be occasionaly carried in through the mains water supply can scratch the glass 3 Detergants which are low quality kept in the machine or humid places can scratch the glass 4 Aluminium objects should not be washed with the glass ...

Page 79: ... adjust the the rinse aid level to low 3 If the water hardness is very low stains which resembles the milk stains can be occured At this condition don t fill the salt and adjust water hardness setting to the lowest position 4 If the salt compartment cap isn t closed properly matt image has been seen as shown on the above picture 5 If there is no salt in the salt compartment calcification might be ...

Page 80: ...n on metal objects which are low quality 4 The customers should be informed about if they wash rusty materials it may cause corrosion on other materials There is calcification on the glasses after the washing 1 Water hardness level can be higher than adjusted level in the machine If it is make the hardness adjustment Recommend to the consumer refining the water for the region where hardness of wat...

Page 81: ...are not related to washing machine They may occur with mains water supply unsuitable program selecting low quality glass products and unsuitable detergant usage All problems base on enviromental condition and the customers usage So the customers should be informed about the machine and the programmes ...

Reviews: