On the 

“General”

tab-sheet, you will find commands that don’t have addi-

tional parameters.

VERSION:

Get software version of IF SMI RS-485 module.

GETGENSTAT:

Get general status (motor present / motor ready).

AUTO_ADDR:

Start the auto-address sequence, in case of address

conflicts.

6.4 General commands

In the 

“Send/Receive”

section, you can monitor the communication between

PC and IF SMI RS-485 module.You will see the Transmit and Receive data

stream.

6.5 Send / Receive

On the 

“Motor ID”

tab-sheet, you will find the “Motor ID” based com-

mands. The motor you want to address, can be selected with the spin edit
box (in the dark gray part, behind Motor ID). Motor ID can be set from “0”
to “15”. Next, press a command button, like “GET_SERIAL”, “GET_PARAM”,
“SET_SMI_ID”, “GET_POS1”, “SET_POS1”, “GET_POS2”, “SET_POS2”
or “GETDETSTAT”.

Remark:

Some commands need additional parameters. See section

“5. Protocol”

for detailed information.

6.3 Motor ID based commands

On the 

“Motor Mask”

tab-sheet, you will find the “motor mask” based

commands. With the checkboxes 15 to 0 you can select which motor(s)
you want to address, or simply select “All”, to address all motors. Next,
press a command button, like “UP”, “DOWN”, “STOP”, “STEP_UP”,
“STEP_DOWN”, “SET_POS”, “SET_TILT”, “SET_POS_STEP_UP”,
“SET_POS_STEP_DOWN”, “GOTO_POS1” or “GOTO_POS2”.

Remark:

Some commands need additional parameters. See section

“5. Protocol”

for detailed information.

6.2 Motor Mask based commands

Summary of Contents for IF SMI RS-485 Series

Page 1: ...e SMI has been de veloped for the connection of intelligent drives for roller shutters and sun protection systems SMI enables to transmit telegrams from control system to the drive and vice versa With...

Page 2: ...ave ID LEN Message length without CRC CMD Command byte DATA Optional data bytes CRC16 16 bits checksum LSB first The IF SMI RS 485 module has 4 DIP switches which represents the base address of the mo...

Page 3: ...of steps 1 255 in DOWN direction 1 step is defined as 2 rotation of the output shaft of the SMI motor The IF SMI RS 485 module responds to this request with a general status message MSG_GETGENSTAT Th...

Page 4: ...15 PAR0 1 Index of the motor parameter PLEN Length of parameter 1 2 or 4 bytes Response SID LEN CMND SMIID VAL0 VALn CRC16 SMIID SMI address of motor 0 15 VAL0 n Parameter value 1 2 or 4 bytes in siz...

Page 5: ...16 bit intermediate position 2 5 5 Status commands define MSG_GETGENSTAT 0xA0 define MSG_GETDETSTAT 0xA1 5 5 1 MSG_GETGENSTAT This message requests the general status of the system Message SID LEN CMN...

Page 6: ...ID based com mands The motor you want to address can be selected with the spin edit box in the dark gray part behind Motor ID Motor ID can be set from 0 to 15 Next press a command button like GET_SERI...

Page 7: ...ifications Vestamatic GmbH Art Nr 85301221 E1 Vestamatic GmbH Dohrweg 27 D 41066 M nchengladbach www vestamatic com IF SMI RS 485 7 1 Wiring diagram IF SMI RS 485 LoVo 7 2 Wiring diagram IF SMI RS 485...

Reviews: