8 About the Boiler
1 3 Specifications
.
Model
VC 100 COMBI
VC 120 COMBI
VC 140 COMBI
Installation Type
Indoor Wall-Hung
Weight
60Ib
72Ib
72Ib
Dimension (H
ⅹ
W
ⅹ
D)
31.5”
ⅹ
18.2”
ⅹ
8.8”
31.5”
ⅹ
18.2”
ⅹ
9.4”
31.5”
ⅹ
18.2”
ⅹ
9.4”
Heat Input
Space Heating
(Min/max)
22,000 Btu/h
/ 100,000 Btu/h
30,000 Btu/h
/ 120,000 Btu/h
30,000 Btu/h
/ 140,000 Btu/h
Domestic Hot
water
(Min/Max)
22,000 Btu/h
/ 130,000 Btu/h
30,000 Btu/h
/ 180,000 Btu/h
30,000 Btu/h
/ 190,000 Btu/h
Gas Supply
Pressure
N G
3.5 ~ 10.5”
W.C
L P
8.0 ~ 13.5”
W.C
Power
Supply
Main Supply
120Volts 60Hz Use less than 5 Amp
Power Combution
145W
190W
210W
Ignition System
Electric Ignition
Gas Valve System
Combination Modulating
Water Pressure
30 psi
Connection
Gas
NPT 3/4”
NPT 3/4”
NPT 3/4”
Space Heating
NPT 3/4”
NPT 3/4”
NPT 3/4”
Domestic
Hot Water
NPT 1/2”
NPT 3/4”
NPT 3/4”
Flue System
Direct Vent
Venting
PVC, C-PVC, Polypropylene 3inch / 50ft
Safety Device
Flame Rod, APS, Temperature sensor,condensate water
level sensor, Temperature limit Device etc