background image

 

 

Z-Wave Information 

Device Type:

 On/Off Power Switch 

Role Type:

 Always On Slave (AOS) 

Command Class Support/Control 
Mandatory CC Support: 

Association CC, v2 or newer 
Association Group Information CC 
Meter CC, v2 
Basic CC 
Binary Switch CC 
Device Reset Locally CC 
Manufacturer Specific CC 
Powerlevel CC 
Version CC, v2 or newer 
Z-Wave Plus Info CC 

Recommended CC Support: 

Firmware Update Metadata CC 

 

Z-Wave’s Groups (Association Command Class Version 2) 

The Switch can be set to send reports to associated Z-Wave devices. It supports one association group with five 
node support for Grouping 1. For grouping 1, the Switch will report its latest status to Z-Wave Gateway/Panel. 

Grouping 1 includes:

 

Binary Switch CC (SWITCH_BINARY_REPORT) 

Meter CC, v2 (METER_REPORT_COMMAND) 
Device Reset Locally CC (COMMAND_CLASS_DEVICE_RESET_LOCALLY) 

 

Auto report to Grouping 1 (Maximum Node 5) 

 

On/Off Event Report 
When toggling between On/Off, it will send Binary Switch Report to the nodes of Grouping 1. 

 

Factory Reset 

When the Power Switch is reset to factory default, it will send Device Reset Locally to all nodes in Group 1. 