Vesta GL-788 Operation Manual Download Page 3

Important safety warnings and precautions

Installation warnings

04

05

Warning Legend

WARNING

The following symbols are used for different levels of warning.

DANGER

DANGER

CAUTION

: Could cause personal injury or have an adverse effect on health.

: Could cause damage to ionizer and possibly void your warranty.

: Please read these pages carefully. They contain very important information 

  to protect you and the valuable warranty on your ionizer.

If you have a chronic disease or serious health issue then please consult with a

healthcare provider before using the ionizer.

Do not drink alkaline water if you have achlorhydria.
 
Consult a healthcare provider before using acidic water if you have:
- Sensitive skin
- Allergies

Only use potable drinking water in your ionizer.
If on hard water please ask about pre-treatment options
Well water and water from smaller systems  should be tested for safety before 
using with an ionizer, and may require pre-filtering.

If you have never consumed alkaline water – start off with the lowest alkaline setting (level 1) 
to begin with. Let your body adjust slowly and naturally for 4-7 days. After this initial adjustment 
period, you may gradually increase the alkalinity of the water.

Customers in hard water areas may need additional treatment otherwise risk voiding their valuable

warranty. If unsure about the quality of your water please contact a water specialist.

Precautions : Do not use the following types of water.

Contaminated

Salt water or Softened water

Turbid water

Hot water over 104 Fahrenheit / 40 Celsius

Do not use your ionizer at 

voltages other than specified 

(AC 110V FOR USA). Use a GFI 

outlet. Do not plug in your 

ionizer where it will exceed 

the rating of outlet or electric 

wiring. Failure to do so can 

result in fire, injury and/or 

damage to yourself, wiring or 

ionizer!

Protect your ionizer from 

freezing temperatures or from 

direct sunlight.

When using the unit in a cold 

place, remove the filter after 

use to prevent the filter from 

freezing.

The acidic water hose should 

be installed so that the end is 

lower than the connection at 

the elbow on the ionizer. The 

water should flow freely down 

from the elbow.

Be sure that the ionizer is 

connected to a COLD water 

source. Connecting it to a hot 

water source could damage 

the water cell or other parts 

of the ionizer.

Keep the power cord and your 

ionizer away from hot surfaces 

or appliances - failure to do 

so may result in electric shock 

or fire!

Do not try to fix the ionizer 

yourself. Call the dealer to 

have it fixed by a qualified 

technician.

Don't move the unit by the 

front cover. The unit could be 

damaged or cause you bodily 

injury if the cover falls off and 

the main body falls.

Move the unit by putting both 

hands underneath it. This will 

prevent the unit from falling 

during movement.

Don't use the unit in a dusty 

place. This may cause the unit 

to malfunction.

If the power cord develops a 

break or short, stop using the 

unit and call customer service 

to have it replaced.

Summary of Contents for GL-788

Page 1: ... VESTA ALKALINE WATER IONIZER OPERATION MANUAL Ver P UK Manufactured by GL Group Co Ltd Warning Incorrect installation and or operation could void your valuable warranty Please protect your investment Read this manual carefully ...

Page 2: ...an other 7 electrode ionizers Sleek mirror faced elegant design by Samsung Aesthetic touch screen sensors You have just purchased the finest most advanced water system in the world Your new ionizer is designed to provide you with many years of the cleanest healthiest and most functional water available There are many specific uses and benefits of this amazing water so read this manual carefully to...

Page 3: ...ecialist Precautions Do not use the following types of water Contaminated Salt water or Softened water Turbid water Hot water over 104 Fahrenheit 40 Celsius Do not use your ionizer at voltages other than specified AC 110V FOR USA Use a GFI outlet Do not plug in your ionizer where it will exceed the rating of outlet or electric wiring Failure to do so can result in fire injury and or damage to your...

Page 4: ... Name of parts Back Name of parts Base 1 7 8 2 6 6 Speaker grill 7 Wall mount hole 8 Filter covers L R 1 Water outlet cap 2 Flexible hose 3 Display indicators 4 Buttons 5 Water supply valve Knob 3 4 5 User manual Tubing Reagent drops Fuse Flexible hose Diverter and screw anchors 10 9 11 9 Water Inlet 1 4 10 Power switch On Off 11 Power socket 12 Water outlet PVC 12 ...

Page 5: ... acidic water is being extracted now Second grade acidic water is being extracted now Third grade acidic water is being extracted now When automatic cleaning is on When Alkaline water is selected When Acidic water is selected When Purified water is selected Place the water ionizer near the sink where the ionizer will be installed 1 2 4 5 6 3 Remove the aerator from the faucet Remove the compressio...

Page 6: ...ood time to double check and make sure all your fittings are tight and the tubing is secure in the fittings Check daily for any leaks during the first week after installation and check for leaks occasionally thereafter CAUTION When switching from Acidic water to Alkaline water let the water run for 5 seconds before drinking Run acidic water through the unit for 10 to 15 seconds each day before dri...

Page 7: ...8 5 pH 7 5 8 5 pH 8 5 Open When using during the first seven days After getting used to the water Push in on the snap tabs and slide the filter cover over as indicated to open 1 Rotate the bezel in the direction indicated by the arrow to open 2 Pull the filter down as shown 3 Tilt the filter out and remove the old filter 4 Insert the bottom of the filter to match the valve base Tilt the new filter...

Page 8: ... F00 F14 Press the Acidic button to cycle backwards through the functions F14 F00 1 2 To adjust a specific function cycle through the function list F00 F14 until the specific function number you wish to change appears in the ORP display window To cycle forward through the function settings press the Purifier button To cycle backwards through the function settings press the Filter Reset button The ...

Page 9: ...ing grade 19 0 19 Voltage from 19 to 19 for Alkaline Water Setting description Setting description pH Function setting code Setting code ORP F00 F01 F02 F03 Setting description Setting description pH Function setting code Setting code ORP F04 F05 F06 F07 Setting grade 19 0 19 Voltage from 19 to 19 for Acidic Water Setting grade 19 0 19 Voltage from 19 to 19 for Acidic Water Setting grade 19 0 19 V...

Page 10: ...ting code Setting code ORP F11 F12 F13 F14 1 Korean 2 Chinese 3 English and 4 Spanish There are 4 cleaning modes available 1 This is the mode that allows pre and post cleaning with the Now cleaning announcement 2 Pre cleaning with the Now cleaning announcement and Post cleaning no announcement is made 3 Post cleaning only with the Now cleaning announcement 4 Post cleaning no announcement is made V...

Page 11: ...t acidic water flow through the unit for 3minutes or more If the water does not improve replace the filter Remove the drain hose from water Even though the filter has been replaced the filter life indicator still shows no life Did you reset the filter counter Reset the filter by pressing the filter replacement button There is a strange noise coming from the unit Unknown Switch off and stop using t...

Page 12: ...22 23 Product specifications Memo Product specifications Memo Temperature shut down GL 788 LCD indication 230W Hollow ultra fiber Sediment Filter optional 100 250Vac 50 60Hz 15 5 X 12 x 6 75 ...

Reviews: