WGC-IT / GC-IT Model:
18
- 2
4
Installation and Maintenance
6HUYLFH0DQXDO
6WHSV
3URFHGXUH
3RLQWV
6. Remove electrical box
■
Disconnect the cable
clamp
a
Remove Temperature
Sensor; Disconnect the
connection wires.
Twist off the earthing screw
fixing the evaporator;
Pull out the all the wiring
terminals
b
Pay attention to the direction
of the retainer of the
thermistor so that the
retainer will not touch the
harness (same as the
existing models.)
Terminal
board
Connecting
wires
Heat exchanger thermistor
Remove a screw on the
electrical box.
c