Turn on the unit
and wait 1 minute
Use DC voltmeter
to measure the
voltage on the two
ends of electrolytic
capacitor
Voltage higher than 200V?
Fault with the voltage
testing circuit on
control panel AP1
Replace the control
panel AP1
Measure the AC voltage between
terminal L and N on wiring board
XT(power supply)
Voltage within
210VAC~250VAC?
Shut down the power
and repair the power
supply to restore the
range
210VAC~250VAC
power on and
restart the unit
If the fault is
eliminated?
Shut down the power and wait 20 mi
nutes; or
use DC voltmeter to measure the voltage
on the two ends of capacitor (test3), until
the voltage is lower than 20V
Check the
connection of reactor
(L in the Electrical
Wiring Diagram)
If the wiring of
reactor L is normal?
Connect the reactor
Laccording to Elec-
trical Wiring Diagr-
am correctly
Re-energize and
turn on the unit
If the fault is
eliminated?
End
Replace the control
panel AP1
Summary of Contents for GH18E
Page 4: ... 7HFKQLFDO QIRUPDWLRQ WGH E GH E Model 18 24 6HUYLFH 0DQXDO GH 24 E 2XWGRRU 8QLW GH 18 E ...
Page 73: ...WGH E GH E Model 18 24 QVWDOODWLRQ DQG 0DLQWHQDQFH 6HUYLFH 0DQXDO 8QLW ...
Page 81: ...WGH E GH E Model 18 24 QVWDOODWLRQ DQG 0DLQWHQDQFH 6HUYLFH 0DQXDO GH 24 E ...
Page 83: ...WGH E GH E Model 18 24 QVWDOODWLRQ DQG 0DLQWHQDQFH 6HUYLFH 0DQXDO GH 24 E ...
Page 115: ...Vidicon Ltd Commercial Air Conditioners R410A Systems ...