4
Product Specifications
Eraser
Model :
No.F12E-E
Ion generation method
: High voltage AC corona discharge
Output voltage
: AC2.4k
V
Input voltage
: DC24
V±
5
%
375
mA(
typ.
)
Dimensions :
H180
×
W142
×
D87
(
H200
×
W151.5
×
D95 including stand
)mm
Weight
: 1.4 kg
Fan speed
: 3.25m
3
/min
(
Max. fan speed
)
Noise emission
: 58.1
d
B(A) Max. fan speed
(
Measured at 1m
)
Ozone generation
: 0.05ppm or less (Measured at 50mm
)
Warning output
: High voltage alarm (Red LED), stop due to fan lock
(
Red LED
)
Protective function
: Fan motor rotation monitoring function (Detecting rotation lock)
: High-voltage output shut down function
(
overload detection
)
: Front cover safety device (circuit cut off when open)
Working ambient
temperature / humidity
: 5
~
40
℃
/ 35
~
65%
RH
(No dewing)
Distance from
target area
: 150
~
900mm
(
Installation location: Non-dangerous indoor location
)
Static electricity
removal time
: Refer to the items in the capabilities chart.
Ion balance
: Within
±
5V (At 300mm)
Air filter
: Pre-filter
Material
: Casing ... Steel with coated finish, :Stand ... Stainless
: Front Cover... ABS, :Electrode ... Inconel
Accessories
・
Adapter
No.AD24-IT
Rated input voltage
:
AC100V-240V(50/60Hz)
0.4A
Rated output voltage
:
DC24V
0.75A
Working
temperature /humidity
:
0~40
℃
10~85%RH
(
No dewing or freezing
)
Cable length
:
DC input cable:1.8 m , AC output cable:1.8m
Weight
:
135g
Consumables
Wire plate
:
F-12EH Filter
:
F-12EF
*The measurement values were obtained using the VESSEL measurement environment, so error could
be induced depending on the operation environment.
Summary of Contents for STAT-CLEAN F12E-E