background image

III.BATTERY USAGE

13

Summary of Contents for ADWAT102C

Page 1: ...ADWAT102C WATCH USER MANUAL 1 ...

Page 2: ...e security questions and answers and the call in password which is used for call centre purpose Make sure you note the details you entered especially the username and password Make sure the agreement is checked and then click on submit If the submit button do not work please click on agreement and click YES button on the pop up window and then click submit again Once you submit it will take you to...

Page 3: ...ories 2 Appearance and Interface 3 Interface Definition III BATTERY USAGE 1 Charge the Battery 2 Notice IV OPERATION METHOD OF BASIC FUNCTIONS 1 Setting Up The Watch 2 Location Inquiry 3 Adjust Receiver Volume 4 Function Settings 5 Zigbee Interface 6 Medicine Reminder 7 Time Zone 8 ECG Interface 9 Low Voltage Alarming Functions 3 ...

Page 4: ...n of CDMA and GPS technologies This model with its precise dimensions and compact appearance expresses the advanced workmanship in the CDMA and GPS field It is a typical design combining communication products and GPS services I GENERAL 4 ...

Page 5: ...al carefully and always use correct operation methods to prevent any possible errors This user s manual is for reference only If some contents and operation steps are inconsistent with those for the actual product the latter will prevail 5 ...

Page 6: ...s watch through the built in GPS tracker Medicine reminders can be set in it to remind the patient of the time when he has to take some medicine or has to go in for some health check up While the health is being monitored an alarm from the watch can signal bad health In case this happens the elderly and your loved ones in problem can be taken to the hospital on time and their life can be saved Web...

Page 7: ...and the most advanced GPS chip Can work effectively in limited space such as urban canyon Low energy consumption Fast signal acquisition Supports single positioning and continuous tracking Supports alarming and remote monitoring Supports fast dial button Supports the location information inquiry by SMS and Internet May monitor without disturbing the tracked person and realizes real time tracking C...

Page 8: ...ays standby time 3 Hours talk time Dimensions L W H 58 9 46 5 13 9 mm Strap 132 9mm and 85 5mm Sensors Accelerometer 2 4 6 8 16 g linear acceleration full scale Gyroscope 245 500 2000 dps angular rate full scale Magnetometer 2 4 8 12 gauss magnetic full scale UV Sensor The UV Index is a number linearly related to the intensity of sunlight reaching the earth Values range from 1 to 11 Ambient Light ...

Page 9: ...II USAGE PREPARATION 9 ...

Page 10: ... Main unit USB cable Charger Headset cable optional Battery 2 1 ACCESSORIES 10 ...

Page 11: ...his watch The bottom left and right buttons are for emergency SOS RED button and call centre GREEN button respectively The upper left button is to switch on and hold on The middle left button serves interface switch and menu The upper right button is for switching on Zigbee and ECG 11 ...

Page 12: ...trength is indicated on the upper left corner of the main interface The middle left button is used to switch among interfaces like Analog Digital Menu The display or wallpaper would be the time in digital or analog model as shown in the picture 12 ...

Page 13: ...III BATTERY USAGE 13 ...

Page 14: ...ct is 4 5 hours Put the charging pin in the terminal and connect the charger to 100V 220V AC power supply to charge the battery Then the power indicator on the upper right corner of the terminal screen will keep strolling as shown in the picture When the battery is fully charged the power indicator will stop strolling and if the battery is charged on switch off mode the picture indicates that the ...

Page 15: ... in time before the terminal automatically shuts down or being alarmed with low power The standby duration and call duration offered by the supplier is calculated in perfect functional mode in practice working hours of the battery may vary due to difference of internet service functional mode and usage mode Disconnect the terminal from charger as soon as possible after the battery is well charged ...

Page 16: ...IV OPERATION METHOD OF BASIC FUNCTIONS 16 ...

Page 17: ...UNCTION Since predetermined number is set no other calls would work on this watch Incoming calls can be rejected by pressing the upper left button and received by pressing bottom left button RED When an emergency button is pressed an alert will be sent to the Emergency team and the customer s next of kin The Emergency and the VESAG Call center team would be available 24 7 4 1 SETTING UP THE WATCH ...

Page 18: ...he call center will immediately contact the caller and give their location information This will be passed to the caller s next of kin as well if required The guardian may inquire the location information of the wearer by web portal on the dash board with the location displayed on the map as shown in picture 4 2 LOCATION INQUIRY 18 ...

Page 19: ...NGS Function settings include Zigbee Alarm Time zone and ECG Enter setting interface by pressing the menu button middle left for twice Press upper right button or bottom right button to toggle the menu Press the bottom left button Red button to save the setting Press the menu button middle left button to withdraw from that interface 19 ...

Page 20: ... of alarms and each group can have 5 different reminders at the same time as shown in the picture above If there is only one medicine in a particular time it would show the time medicine name and anything else like address or phone number according the wearer s choice when the alarm rings When the clock alarms the interface will switch to reminder interface automatically Press the upper or bottom ...

Page 21: ...T of your country The red button can be used to select the appropriate GMT and the buttons on the right hand side can be used to scroll up and down to select Once the time is selected the time and date on the screen will automatically update accordingly 21 ...

Page 22: ...VESAG ECG device pairs up with the VESAG watch Once the zigbee is ON and when a request is sent to ECG by selecting Request ECG using the red button it starts connecting to the ECG device and also automatically starts updating the web portal unless Stop sending ECG is opted as shown in the picture 22 ...

Page 23: ...r and needs to be charged an alarm would be sent immediately as follows Battery is low Please charge in time This can be activated in the application by logging in with your username and password 4 9 LOW VOLTAGE ALARMING FUNCTION 23 ...

Page 24: ...s device will not be able to work in case of power off and out of the service area even if you are a registered user This device supports the dual positioning mode of GPS and CDMA Please use this device in a legal area any illegal consequence will be borne by the user Note Due to the high sensitivity of the GPS module adopted by this product it is normal to be drifting with weak GPS signal 24 ...

Page 25: ...he above checks and demonstrations have been done to my full satisfaction and that I am totally satisfied with the installations and performance of the VESAG watch To be filled by Issuer IMEI Delivered On Tick appropriate Any transit damage yes no Warranty terms explained Y N Basic demo given Y N Date Time Signature of the customer Customer name Address Installed by Telephone 25 ...

Page 26: ...centre and the product is found free from transit damage The customer shall have to pay a visiting charge towards inspection as applicable 6c In case of any transit damage the product shall be repaired by the concerned service centre on charges and warranty for unexpired period to continue The warranty does not cover demonstration installation of the product purchased The company s obligation unde...

Page 27: ...ction manual Defects caused by improper use as determined by the company personnel Modification or alteration of any nature is made in the electrical circuitry or physical construction of the set Installation repair work is carried out by persons agency other than authorized by the company Site premises where the product is kept conditions that do not confirm to the recommended operating condition...

Page 28: ...t SAR The device complies with RF specifications when the device used at 0mm from your body SAR Max values 1 85 W Kg 10g for extremity 0 85 W Kg 1g for next to mouth 1 861 W Kg of The Highest simultaneous SAR value ...

Reviews: