background image

Figure 3.3 Convert the Liebert PSI XR for rack installation

WARNING! Risk of top-heavy unit falling over. May cause equipment damage, personal injury or
death.Placing heavy equipment near the top of a rack may increase the risk of tipping. Place the
UPS or battery cabinet, if one is being used, in the bottom of the rack.

CAUTION: Risk of strain from lifting heavy equipment. May cause personal injury.Lifting
equipment into rack may be a two-person job, depending on weight of equipment.

NOTICE

When rack-mounted, the UPS must be supported by a shelf, slide rails, brackets or fixed rails on
each side. The rack mount handles WILL NOT support the weight of the UPS. They are used to
move the UPS into and out of the rack.

3.4 Orient Display for Installation

The Liebert PSI XR features a rotating display that may be oriented for either tower or rack installations.

To set the display for your installation, pull out on the display and rotate it until it is oriented correctly,
then press it into the UPS until it is seated.

Vertiv

| Liebert® PSI XR™ User Manual |

11

Summary of Contents for Liebert PSI XR 1000

Page 1: ...Liebert PSI XR 1000 1500 2200 3000 120VAC User Manual...

Page 2: ...any installation or operational issues with your product check the pertinent section of this manual to see if the issue can be resolved by following outlined procedures Visit https www VertivCo com e...

Page 3: ...ors 17 4 1 Control Buttons 17 4 1 1 On Alarm Silence Manual Self Diagnostic Test 17 4 1 2 Off Button 18 4 2 Status Indicators 18 4 2 1 Status Change Button 18 4 2 2 Load Level Indicator 18 4 2 3 Batte...

Page 4: ...7 2 Internal Battery Replacement Procedure 25 8 Specifications 27 9 Troubleshooting 31 Vertiv Liebert PSI XR User Manual ii...

Page 5: ...S has no user serviceable parts inside except the internal battery pack Operate the UPS only from a properly grounded earthed 220 240 VAC 50Hz or 60Hz AC supply Do not supply this UPS from electrical...

Page 6: ...Vertiv Liebert PSI XR User Manual 2 This page intentionally left blank...

Page 7: ...by important instructions Indicates the unit contains a valve regulated lead acid battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON Alarm Silence Manual Self Diag...

Page 8: ...Vertiv Liebert PSI XR User Manual 4 This page intentionally left blank...

Page 9: ...combination ON Alarm Silence Manual Self Diagnostic button an Off button and a Display Status Change button The Liebert PSI XR has USB DB 9 RS 232 contact closure and SNMP interface ports The DB 9 and...

Page 10: ...Figure 1 3 2200 and 3000VA rear view Vertiv Liebert PSI XR User Manual 6...

Page 11: ...nual on CD Liebert Shutdown Software and User Manual on CD DB 9 Serial Cable USB Cable Input Power Cord 2200 3000 only 2 IEC Output Cable 1000 1500 only 2 IEC Output Cable 2200 3000 only 3 Tower Stand...

Page 12: ...Vertiv Liebert PSI XR User Manual 8 This page intentionally left blank...

Page 13: ...ermine the method that suits the application and proceed Decide where to install the Liebert PSI XR The UPS must be installed indoors in a controlled environment Place it in an area with unrestricted...

Page 14: ...wer Stand 3 3 Rack Mount UPS Conversion and Installation See Figure 3 3 on the facing page when installing the Liebert PSI XR in a rack External battery cabinets are installed in racks in the same man...

Page 15: ...may be a two person job depending on weight of equipment NOTICE When rack mounted the UPS must be supported by a shelf slide rails brackets or fixed rails on each side The rack mount handles WILL NOT...

Page 16: ...unit Off and proceed to Connect Input Power and Load below 3 6 Connect Input Power and Load The 1000VA and 1500VA models do not include an input power cable the 2200VA and 3000VA UPSs include an inpu...

Page 17: ...Connect a 10 base T 100 network cable to the RJ 45 network surge protection IN jack on the rear of the UPS Connect from the OUT jack with network cabling to network equipment see Figure 3 6 below Figu...

Page 18: ...e software See the Liebert MultiLink quick start guide or user manual for installation instructions Connect one end of the USB cable supplied to the USB port on the rear of the UPS Connect the other e...

Page 19: ...Install the external battery cabinet in a tower configuration or in a rack see Figure 3 9 below or Rack Mount UPS Conversion and Installation on page 10 3 Connect the external battery cabinet cable t...

Page 20: ...3 230XR 24VDC Red PSRT3 24VBXR PS1500RT3 230XR PS2200RT3 230XR 48VDC Gray PSRT3 48VBXR PS3000RT3 230XR Table 3 1 Battery cabinet connector color key Figure 3 10 Connect battery cabinets to UPS See Tab...

Page 21: ...LED 5 Overload UPS Overload 1 to 5 Load Battery Level Indicate Load Battery Level 6 Status Change Button Switches Display from Load Level Indicators to Battery Level Indicators 7 OFF Button UPS Off 8...

Page 22: ...indicated UPS Fault Contact your local dealer Vertiv representative or Liebert Applications NOTE Refer to Figure 4 1 on the previous page and Table 4 1 on the previous page for details about the LEDs...

Page 23: ...AVR Boost Buck Mode the LED display will indicate the relative load level on the output of the UPS and will flash LED 1 boost or LED 2 buck to indicate the mode Weak Battery When the UPS battery volt...

Page 24: ...erload Red Flashes Battery Fault Shutdown Yellow Steady Red Steady Overload Shutdown Red Steady Red Steady UPS Output Abnormal Shutdown Yellow Steady Red Steady Table 4 2 Status indicators color illum...

Page 25: ...atteries 5 3 Battery Mode The UPS switches to Battery Mode in the event of an extreme input voltage frequency condition or mains failure When the UPS is in Battery Mode the Battery Indicator illuminat...

Page 26: ...Vertiv Liebert PSI XR User Manual 22 This page intentionally left blank...

Page 27: ...5 12V on battery operation 5 Common 6 Output Off short to Pin 5 non latching any mode operation 7 Low Battery open emitter 8 Mains Fail open emitter 9 Mains Fail open collector Table 6 1 DB 9 pin assi...

Page 28: ...shutdown software continually monitors the UPS and can shut down your computer or server via USB and RS 232 in the event of an extended power failure The Liebert IS WEBRT3 provides SNMP and Web based...

Page 29: ...uations and power failures To replace the batteries 1 Remove the two screws on the left side of the front bezel 2 Pull the front bezel off the UPS 3 Remove the two screws on the battery bracket 4 Remo...

Page 30: ...Figure 7 1 Battery replacement Vertiv Liebert PSI XR User Manual 26...

Page 31: ...C14 IEC 320 C20 IEC 320 C20 Output Sockets 6 IEC 320 C13 6 IEC 320 C13 6 IEC 320 C13 1 IEC 320 C19 6 IEC 320 C13 1 IEC 320 C19 Voltage Normal Mode 220 230 240 VAC configurable Voltage Battery Mode 220...

Page 32: ...000RT3 230XR PS1500RT3 230XR PS2200RT3 230XR PS3000RT3 230XR Dimensions W x D x H mm in Unit 440 x 490 5 x 88 17 3 x 19 3 x 3 5 Shipping 560 x 675 x 228 22 x 26 6 x 9 Weight kg lb Unit 29 64 Shipping...

Page 33: ...24 241 170 139 50 181 131 95 73 75 126 84 62 50 100 96 64 48 31 Internal Battery 4 External Battery Cabinets 10 789 627 483 329 25 385 308 255 171 50 233 167 143 95 75 162 114 100 62 100 124 82 72 47...

Page 34: ...Vertiv Liebert PSI XR User Manual 30 This page intentionally left blank...

Page 35: ...h to AC dark start UPS not plugged in Plug in the power cord securely Circuit breaker tripped Reset the circuit breaker AC overvoltage Wait until voltage drops to an appropriate level or have the util...

Page 36: ...Vertiv Liebert PSI XR User Manual 32 This page intentionally left blank...

Page 37: ......

Page 38: ...logos referred to are trade names trademarks or registered trademarks of their respective owners While every precaution has been taken to ensure accuracyand completeness herein Vertiv Co assumes no re...

Reviews: