DANGER!  

Warns of a hazard the reader 

will

 be exposed to that will 

likely

 result 

in death or serious injury if not avoided. (ANSI, OSHA) 

 

WARNING!  

Warns of a potential hazard the reader 

may

 be exposed to that 

could 

result in 

death or serious injury if not avoided. This admonition is not used for situations that pose a 
risk only to equipment, software, data, or service. (ANSI) 

 

CAUTION!  

Warns of a potential hazard the reader 

may

 be exposed to that 

could

 

result in minor or moderate injury if not avoided. (ANSI, OSHA) This admonition is not 
used for situations that pose a risk only to equipment, data, or service, even if such use 
appears to be permitted in some of the applicable standards. (OSHA) 

 

ALERT!  

Alerts the reader to an action that 

must be avoided

 in order to protect 

equipment, software, data, or service. (ISO) 

 

ALERT!  

Alerts the reader to an action that 

must be performed

 in order to prevent 

equipment damage, software corruption, data loss, or service interruption. (ISO) 

 

FIRE SAFETY!  

Informs the reader of fire safety information, reminders, precautions, 

or policies, or of the locations of fire-fighting and fire-safety equipment. (ISO) 

 

SAFETY!  

Informs the reader of general safety information, reminders, precautions, or 

policies not related to a particular source of hazard or to fire safety. (ISO, ANSI, OSHA) 

Summary of Contents for eSure 60017372

Page 1: ...eSure Power Extend Converter Mounting Bracket and Door Kit Installation Manual IM60017372 Revision C Kit Specification Number 60017372...

Page 2: ...thorization from Vertiv Group Corp is strictly prohibited 2020 Vertiv Group Corp All rights reserved Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp All other n...

Page 3: ...ing Equipment Containing Static Sensitive Components 6 Static Warning 6 eSure Power Extend Converter Mounting Bracket and Door Kit Installation Instructions 7 Kit Description 7 Tools and Material Requ...

Page 4: ...e injury if not avoided ANSI OSHA This admonition is not used for situations that pose a risk only to equipment data or service even if such use appears to be permitted in some of the applicable stand...

Page 5: ...ld be performed in the order indicated b Remove watches rings and other metal objects c Prior to contacting any uninsulated surface or termination use a voltmeter to verify that no voltage or the expe...

Page 6: ...ipment contains static sensitive components The warnings listed below must be observed to prevent damage to these components Disregarding any of these warnings may result in personal injury or damage...

Page 7: ...ield install an eSure Power Extend Converter using one of the kits listed in Table 1 Installation of this kit in other systems not listed in Table 1 should not be attempted Table 1 Power System Mounti...

Page 8: ...asher factory assembled to side brackets 4 233362700 6 32 x 3 8 Screw 4 are factory assembled to side brackets 8 60016951 Front Mounting Bracket 1 152175 Hot Surface Label factory assembled to front b...

Page 9: ...te that it was read Important Safety Instructions DANGER Adhere to the Important Safety Instructions starting on page 5 and those listed in the power system manual CAUTION When performing any step in...

Page 10: ...ent the kit supplied left side mounting bracket as shown in Figure 2 Secure to distribution panel with kit supplied hardware as shown in Figure 2 Torque hardware as indicated in Figure 2 Figure 2 Inst...

Page 11: ...nt mounting bracket as shown in Figure 3 Secure the front mounting bracket to the left side mounting bracket as shown in Figure 3 DO NOT TIGHTEN HARDWARE hardware will be tightened during power extend...

Page 12: ...ibution panel with kit supplied hardware as shown in Figure 4 Torque hardware as indicated in Figure 4 Secure the front mounting bracket to the right side mounting bracket as shown in Figure 4 DO NOT...

Page 13: ...en installing a power extend converter mounting bracket kit covered by these instructions onto a stand alone distribution cabinet installed in an outside plant enclosure leave the front door off the s...

Page 14: ...ribution panel as a guide record the distribution positions onto the kit supplied label 10 Place the kit supplied distribution position label see Figure 7 back into the kit supplied storage pouch or r...

Page 15: ...Kit P N 566026 12 Continue with the Installing the Power Extend Converter into a Distribution Position procedure starting on page 16 Distribution Position Label Toggle Breaker Guard Kit P N 566026 Ex...

Page 16: ...els pertain to the average output power busy hour average power drawn by the load including any power loss in the cable The peak power available from each unit remains at 1000 watts regardless of spac...

Page 17: ...reaker and verify the load and return cables for the position are wired and labeled correctly At the same time connect the power extend converter return wire faston tab P N 565990 provided with the po...

Page 18: ...60016097 Load Lead Lug 1 4 Flat Washer 1 4 Lock Washer Torque to 72 in lbs 1 4 20 x 5 8 Bolt Load Lead Lug 1 4 Lock Washer 1 4 20 x 5 8 Bolt Torque to 72 in lbs 1 4 Flat Washer Load Return Lead Lug 1...

Page 19: ...re jumper P N 565752 may be installed with the P N 564330 return wire if additional return wire length is preferred NOTE The power extend converter is also furnished with an 8 inch long return wire ju...

Page 20: ...Converter Power Extend Converter Return Wire P N 564330 Power Extend Converter Return Wire Faston Tab P N 565990 Power Extend Converter Power Extend Converter Orient the white square on the return wir...

Page 21: ...epeat for each power extend converter to be installed 5 Secure the power extend converter s to the mounting bracket with the screw provided with the power extend converter Torque as shown in Figure 13...

Page 22: ...Observe the status of the power extend converter front panel local indicator If operating normally this indicator should be illuminated green See Figure 12 on page 21 9 Close and secure the door 10 En...

Page 23: ...Vertiv eSure Power Extend Converter Mounting Bracket and Door Kit Installation Manual IM60017372 Rev C 23 This page is intentionally blank...

Page 24: ...Vertiv com Vertiv Headquarters 1050 Dearborn Drive Columbus OH 43085 USA IM60017372 RC 06 2020...

Reviews: