KEY SEQUENCE
VALUE
ACTION
Ctrl+Ctrl+S+[nn]+Enter
Enter a value between 02 and 60 where nn is the
value format.
Sets the interval scan time; the default setting is
30 seconds.
Ctrl+Ctrl+S+G+Enter
N/A
Starts the interval scan function.
Ctrl+Ctrl+S+H+Enter
N/A
Stops the interval scan function.
Ctrl+Ctrl+SM++Enter
N/A
Enables mouse movement to stop scanning.
Ctrl+Ctrl+SM-+Enter
N/A
Disables mouse movement to stop scanning.
Table 2.7 Scan Mode Commands
2.6 Cascading Units
The switches support one level of switch-to-switch cascading. You can connect a secondary switch to
each port of a primary switch. You can connect targets to each port on a secondary switch, but you
cannot connect additional switches to a secondary switch.
A cascading cable can be used to connect from a target port on the top-tier unit into a console port of the
second-tier unit. You can use a cascading cable or the standard VGA cable for the connection.
Figure 2.6 Cascading Units Example Configuration
ITEM
DESCRIPTION
1
Primary switch - You can connect one secondary switch to each port on the primary switch.
2
Secondary switches - You can connect one target to each port on each of the secondary switches.
3
Secondary switch targets - You can only connect target devices to secondary switches. Secondary switches do not support third-tier switch
connections.
4
Secondary switch connected to port 1 on the 16-port primary switch
Table 2.8 Cascading Units Example Configuration Components
Vertiv
| Vertiv™ AutoView™ AV104/AV108/AV116 Switch Installer/User Guide |
9