W A R N IN G ! User serviceable co m po n en ts (F o r service perso n n el)
A ll equ ipm en t m ain ten an ce an d servicin g pro cedu res in vo lvin g in tern al access requ ires th e u se
o f a to o l an d sh o u ld be carried o u t o n ly by train ed perso n n el. T h ere are n o u ser-serviceable
parts beh in d co vers requ irin g a to o l/k ey fo r rem o val.
W A R N IN G ! B attery vo ltage exceeds 400 Vdc (F o r service perso n n el)
1. A ll ph ysical battery m ain ten an ce an d servicin g pro cedu res requ ires th e u se o f a to o l/k ey an d
sh o u ld be carried o u t o n ly by train ed perso n n el.
2. T ak e special care wh en wo rk in g with th e batteries asso ciated with th is UP S. W h en co n n ected,
th e battery term in al vo ltage will exceed 400 Vdc an d is po ten tially leth al.
3. B attery m an u factu rers su pply details o f th e n ecessary precau tio n s to be o bserved in wo rk in g
o n , o r in th e vicin ity o f, a large ban k o f battery cells. T h ese precau tio n s sh o u ld be fo llo wed
im plicitly. P articu lar atten tio n sh o u ld be paid to th e reco m m en datio n s co n cern in g lo cal
en viro n m en tal co n ditio n s an d th e pro visio n o f pro tective clo th in g, first aid, an d fire-figh tin g
facilities.
W A R N IN G ! G en eral safety (F o r u sers)
1. Lik e o th er types o f large po wer equ ipm en t, th e UP S an d battery circu it break er bo x/battery
cabin et h ave h igh vo ltage in side. A s th e co m po n en ts with h igh vo ltage can be accessed o n ly
wh en th e fro n t do o r is o pen ed, th e risk o f co n tactin g h igh vo ltage h as been m in im ized. T h is
equ ipm en t m eets th e IP 20 stan dard, an d th e o th er safety sh ields are pro vided in side th e
equ ipm en t.
2. T h ere will n o t be an y risk wh en o peratin g th is equ ipm en t acco rdin g to th e gen eral
in stru ctio n s an d th e steps reco m m en ded in th is m an u al.
W A R N IN G ! M u ltiple po wer in pu ts (F o r u sers)
1. T h is UP S system receives po wer fro m m o re th an o n e so u rce. Disco n n ectio n o f all A C so u rce
an d th e DC so u rce is requ ired befo re servicin g.
2. T h is UP S h as several circu its th at are en ergized with h igh A C as well as DC vo ltages. Ch eck
fo r vo ltage with bo th A C an d DC vo ltm eters befo re wo rk in g with in th e UP S.
W A R N IN G ! W h en in tern al fu se o f th e UP S is dam aged, it m u st be replaced with fu se o f th e
sam e electric param eters by qu alified perso n n el.
1 Important Safety Instructions
iv
Vertiv™ Liebert® APM Plus User Manual
Summary of Contents for APM Plus 0500kMK16FN02000
Page 1: ...Vertiv Liebert APM Plus User Manual 50 500 kVA UPS...
Page 8: ...vi This page intentionally left blank Vertiv Liebert APM Plus User Manual...
Page 34: ...2 Overview 26 This page intentionally left blank Vertiv Liebert APM Plus User Manual...
Page 45: ...Four switches 500 kVA 3 Mechanical Installation 37 Vertiv Liebert APM Plus User Manual...
Page 76: ...Figure 5 11 Customize the display 5 Touch Screen 68 Vertiv Liebert APM Plus User Manual...
Page 86: ...Figure 5 20 Enable module redundancy 5 Touch Screen 78 Vertiv Liebert APM Plus User Manual...
Page 91: ...Figure 5 24 Status Gauge setting options 5 Touch Screen 83 Vertiv Liebert APM Plus User Manual...
Page 92: ...5 Touch Screen 84 Vertiv Liebert APM Plus User Manual...
Page 94: ...5 Touch Screen 86 Vertiv Liebert APM Plus User Manual...
Page 95: ...Figure 5 26 Unit status Bypass details 5 Touch Screen 87 Vertiv Liebert APM Plus User Manual...
Page 96: ...Figure 5 27 Unit status Battery details 5 Touch Screen 88 Vertiv Liebert APM Plus User Manual...
Page 97: ...Figure 5 28 Unit status Load details 5 Touch Screen 89 Vertiv Liebert APM Plus User Manual...
Page 100: ...5 Touch Screen 92 Vertiv Liebert APM Plus User Manual...
Page 112: ...5 Touch Screen 104 This page intentionally left blank Vertiv Liebert APM Plus User Manual...
Page 184: ...12 Specifications 176 This page intentionally left blank Vertiv Liebert APM Plus User Manual...