Technical Data 

Ref 

NLT30 

NLT30 

 Measuring range  

0.05 – 60 m   A) 

0.05 – 60 m   A) 

 Measuring accuracy (standard deviation) 

±2.0 mm   B) 

±2.0 mm   B) 

Operating temperature  

-10°C… +40°C  C) 

-10°C… +40°C  C) 

Laser class 

Laser type 

635 nm < 1mw 

635 nm < 1mw 

Laser beam diameter (at 25°C ) approx. distance 
 

 
 at 10 mts = 5 mm 
at 30 mts = 15mm 

 
 at 10 mts = 5 mm 
at 60 mts = 30mm 

Batteries  

2 x 1.5 VLR03 (AAA) 

2 x 1.5 VLR03 (AAA) 

Battery live, approximately Individual measurements  

5000   D) 

5000   D) 

Dimensions 

52.8 x 127 x 26.3mm 

52.8 x 127 x 26.3mm 

Implementation of national standards  

GB/T 14267-2009 

GB/T 14267-2009 

 
A.  The  working  range  increases  depending  on  how  well  the  laser  light  is  reflected  from  the  surface  of  the  target 
(scattered, not reflective) and with increased brightness of the laser point  to the ambient light intensity (interior spaces, 
twilight). In unfavourable conditions (e.g. when  measuring outdoors at intense sunlight), it may be necessary to use the 
target plate. 
B. When meaning within 10m, measurement accuracy is ±2mm; more than 10m, measurement  accuracy is calculated as 
follows; ±2mm ±0.05 *(D-10) (D: Measuring Distance, Unit: m) 
C. In the continuous measurement function, the maximum operating temperature is +40 °C. 
D. Less measurements are possible when using 1.2 V rechargeable batteries than wit 1.5 V  batteries. 
E. In the continuous measurement function, the maximum operating temperature is +40 °C. 
F. Less measurements are possible when using 1.2 V rechargeable batteries than with 1.5 V  batteries. 
 

ASSEMBLY 

Inserting/Replacing the Batteries 
Using alkali-manganese or rechargeable batteries is recommended for operation of the measuring tool. 
Less measurements are possible when using 1.2 V rechargeable batteries than  with 1.5 V batteries. 
To  open  the  battery  lid  10,  press  the  latch  9  in  the  direction  of  the  arrow  and  remove  the  battery  lid.  Insert  the 
batteries/rechargeable batteries. When inserting, pay attention to the correct polarity according to the representation on 
the inside of the battery compartment. 

When the battery symbol  

appears for the first time on the display, at least  100 measurements are still possible. 

When  the battery symbol flashes, the batteries/rechargeable  batteries  must  be  replaced;  measurements  are  no  longer 
possible. 
Always  replace  all  batteries/rechargeable  batteries  at  the  same  time.  Do  not  use  different  brands  or  types  of 
batteries/rechargeable batteries together. 
Remove the batteries/rechargeable batteries from the measuring tool  when not using it for longer periods. When storing 
for longer periods, the  batteries/rechargeable batteries can corrode and self-discharge. 
 

OPERATION 
Initial Operation 

Do not leave the switched-on measuring tool unattended and switch the  measuring tool off after use. Other persons could 
be blinded by the laser  beam. 
Protect the measuring tool against moisture and direct sun light. 
Do not subject the measuring tool to extreme temperatures or variations in temperature. As an example, do not leave it 
in  vehicles  for  longer  periods.  In  case  of  large  variations  in  temperature,  allow  the  measuring  tool  to  adjust  to  the 
ambient temperature before putting it into operation. 
Avoid  heavy  impact  to  or  falling  down  of  the  measuring  tool. After  severe  exterior  effects  to  the  measuring  tool,  it  is 
recommended to carry out an accuracy check each time before continuing to work. 

Summary of Contents for NLT30

Page 1: ...MANUAL DE INSTRUCCIONES USER GUIDE MEDIDOR LASER DISTANCIAS DIGITAL RANGEFINDER REF NLT30 REF NLT60...

Page 2: ...mismo involuntariamente o a otras personas No utilice este aparato en ambientes con art culos explosivos ni con presencia de l quidos inflamables gases o polvos Podr a provocar una explosi n o incend...

Page 3: ...n la luz del sol intensa puede ser necesario el uso de la placa del objetivo B Cuando est dentro de 10 m la precisi n de la medici n es de 2 mm si es m s de 10m la precisi n de la medici n se calcula...

Page 4: ...redefine la medici n Para cambiar el nivel de referencia presionar el bot n 6 Tras la selecci n de la funci n de medici n y el nivel de referencia todos los pasos posteriores se llevan a cabo pulsando...

Page 5: ...e medir la primera distancia pulse el bot n y de nuevo el bot n 1 para medir la distancia que desea a adir Se calcular de forma autom tica el resultado mostrado Despu s de la puesta en marcha si se qu...

Page 6: ...y de nuevo para tomar la segunda medici n La altura de la construcci n tercer lado del tri ngulo en la pantalla aparecer el primer y el segundo valor Preste atenci n a que el punto de referencia de l...

Page 7: ...e lo posible en contra o en los puntos de medici n La medici n tiene lugar en el centro del haz de l ser incluso cuando las superficies de destino son vistos en un plano inclinado Efectos influencia d...

Page 8: ...tiempo despu s MANTENIMIENTO Y SERVICIO Guardar y transportar el aparato s lo en el paquete suministrado Mantenga la herramienta de medici n limpia en todo momento No sumerja la herramienta de medici...

Page 9: ...riginal spare parts This ensures that the safety of the measuring tool is maintained Do not allow children to use the laser measuring tool without supervision They could unintentionally blind other pe...

Page 10: ...the Batteries Using alkali manganese or rechargeable batteries is recommended for operation of the measuring tool Less measurements are possible when using 1 2V rechargeable batteries than with 1 5V...

Page 11: ...selected place the measuring tool against the desired measuring line e g a wall Press the measuring button 1 to switch on the laser beam Do not point the laser beam at persons or animals and do not l...

Page 12: ...n the display Press button 1 to measure the length and the width one after another in the same manner as a length measurement The laser beam remains switched on between both measurements After taking...

Page 13: ...2 four times the symbol appears on display Press button 1 to activate laser and aim at the point which is to be measured Press button 1 again to take the first measurement and again to take the second...

Page 14: ...when measuring on different surfaces Included here are transparent surfaces e g glass water reflecting surfaces e g polished metal glass porous surfaces e g insulation materials structured surfaces e...

Page 15: ...e measuring tool yourself In case of repairs send in the measuring tool packed in its package DISPOSAL This marking indicates that this product should not be disposed with other household wastes throu...

Reviews: