10
Chart 8
8.
Load (AC Output) Connection
WARNING!
It's very important for system safety and efficient operation to use appropriate
cable for AC connection. To reduce risk of injury, please use the proper recommended cable
size as below.
Conductor cross-section (mm2)
AWG no.
≥3.35
10 - 12
Step 1: Remove insulation sleeve 8 mm for three
conductors. And shorten phase L and neutral conductor N 3
mm. Refer to chart 7.
Step 2: Connect wires according to polarities indicated on
terminal block. Be sure to connect PE protective conductor
(
)
first. Refer to Chart 8.
L
→
LINE (brown or black)
→
Ground (yellow-green)
N
→
Neutral (blue)
Step 3: Make sure the wires are securely connected.
CAUTION:
It’s only allowed to connect load to “AC Output Connector”. Do NOT connect
the utility to AC Output Connector.
CAUTION:
This inverter is not allowed to operate in parallel. Please do NOT parallel
connect more than one unit in AC output connector. Otherwise, it will damage this inverter.
Chart 7