8
VXR-7000 UHF Service Manual
Operating Manual Reprint
C
B
A
A
B
Figure 1
FILTER Unit
Switching
Regulator
Unit
Figure 2
Changing Switching Regulator unit AC Mains Jumper Wiring
Before attempting this jumper wire change, remove the
AC power cord from the AC jack on the rear panel.
Referring to Figure 1, remove the 14 screws affixing
the top and bottom covers of the repeater, and remove
the covers.
Remove the eight screws affixing the shield cover for
the FILTER Unit, and remove the cover (see Figure
1).
Disconnect all wires and connectors from the FILTER
Unit, then remove the six screws affixing the Switch-
ing Regulator Unit, and remove it (the Switching
Regulator Unit is mounted with the FILTER Unit: Fig-
ure 2).
Referring to Figure 3, remove the four screws and re-
move the heatsink from the Switching Regulator Unit.
Referring to Figure 4, perform the correct jumper wir-
ing on the Switching Regulator Unit for the AC Mains
voltage used in your area (100-127 VAC or 207-253
VAC).
Replace the heatsink onto the Switching Regulator
Unit, then replace the Switching Regulator Unit onto
the chassis, and connect all wires and connectors to
the FILTER Unit.
Replace the AC fuse (
FH6001
) on the FILTER Unit
according to the AC Mains voltage range:
100 VAC (100-127 VAC): 5A
200 VAC (207-253 VAC): 3A.
Replace the shield cover and replace the top and bot-
tom covers. This completes the wiring change.
Important!
:
If you change the AC voltage range, you must
also change the AC fuse on the FILTER Unit. Do not re-
place with a slow-blow type fuse.
Summary of Contents for VXR-7000
Page 21: ...21 VXR 7000 UHF Service Manual Block Diagram ...
Page 22: ...22 VXR 7000 UHF Service Manual Block Diagram ...
Page 23: ...23 VXR 7000 UHF Service Manual Block Diagram ...
Page 24: ...24 VXR 7000 UHF Service Manual Interconnection Diagram ...
Page 32: ...32 VXR 7000 UHF Service Manual Note ...
Page 36: ...36 VXR 7000 UHF Service Manual PA Unit Lot 1 61 Replaced by PA 2 Unit Note ...
Page 42: ...42 VXR 7000 UHF Service Manual PA 2 Unit Lot 62 Note ...
Page 44: ...44 VXR 7000 UHF Service Manual PA 2 Unit Lot 62 Parts Layout Side B 2 1 a c e f d b g h i 3 ...
Page 52: ...52 VXR 7000 UHF Service Manual TX Unit Lot 1 59 Replaced by TX 2 Unit Note ...
Page 58: ...58 VXR 7000 UHF Service Manual TX 2 Unit Lot 60 Note ...
Page 60: ...60 VXR 7000 UHF Service Manual TX 2 Unit Lot 60 Note ...
Page 66: ...66 VXR 7000 UHF Service Manual TX 2 Unit Lot 60 Note ...
Page 70: ...70 VXR 7000 UHF Service Manual RX Unit Lot 1 59 Replaced by RX 2 Unit Note ...
Page 78: ...78 VXR 7000 UHF Service Manual RX 2 Unit Lot 60 Note ...
Page 80: ...80 VXR 7000 UHF Service Manual RX 2 Unit Lot 60 Note ...
Page 90: ...90 VXR 7000 UHF Service Manual CNTL Unit Note ...
Page 104: ...104 VXR 7000 UHF Service Manual CNTL Unit Note ...
Page 105: ...105 VXR 7000 UHF Service Manual Circuit Diagram Lot 1 107 Display Unit ...
Page 107: ...107 VXR 7000 UHF Service Manual Circuit Diagram Lot 108 Display Unit ...
Page 112: ...112 VXR 7000 UHF Service Manual Display Unit Note ...
Page 117: ...117 VXR 7000 UHF Service Manual Key Unit Circuit Diagram Lot 108 ...
Page 120: ...120 VXR 7000 UHF Service Manual Key Unit Note ...
Page 122: ...122 VXR 7000 UHF Service Manual Key Unit Note ...
Page 124: ...124 VXR 7000 UHF Service Manual Filter Unit 50W Type Note ...
Page 130: ...130 VXR 7000 UHF Service Manual Filter 2 Unit 25W Type Note ...
Page 136: ...136 VXR 7000 UHF Service Manual SW Unit 25W Type Note ...
Page 141: ...141 PS Unit VXR 7000 UHF Service Manual Circuit Diagram ...
Page 145: ...145 VXR 7000 UHF Service Manual ...