TX Power Adjustment

TX Power Adjustment

TX Power Adjustment

TX Power Adjustment

R

 

Connect the wattmeter and dummy load to the antenna jack, and tune the
transceiver to 128.000 MHz.

R

 

Transmit, and adjust 

VR1003

 to obtain 1.5 W RF (carrier) power indicated on the

wattmeter (without audio modulation input).

TX

TX

TX

TX Modulation Adjustment

 Modulation Adjustment

 Modulation Adjustment

 Modulation Adjustment

R

 

Connect the Radio Tester to the antenna jack, then adjust the AF generator output
level for injection of 200 mV rms @ 1 kHz to the MIC jack. Leave the transceiver
tuned to 127.500 MHz.

R

 

Transmit, and adjust 

VR1002

 to obtain 85 % modulation (±3 %) as indicated on the

Radio Tester.

R

 

Reduce the AF generator output level to 20 mV rms, then adjust 

VR1001

 to obtain

30 % modulation (±3 %) on the Radio Tester.

Internal System Alignment Routine

Internal System Alignment Routine

Internal System Alignment Routine

Internal System Alignment Routine
This feature uses a programmed routine in the transceiver which replaces many
previously-complex discrete component settings and adjustments with digitally-
controlled settings via the 

CHANNEL

 selector knob. Transceiver adjustments include:



 

Squelch Hysteresis Adjustment



 

Squelch Threshold Adjustment



 

Squelch “Tight” Adjustment

To begin, set the transceiver to 127.500 MHz, and turn the transceiver off. Then, press
and holding the 

LAMP

 switch, 

PTT

 switch and the 

CHANNEL

 selector knob while

turning the transceiver on.

€

 

Squelch Hysteresis Adjustment (HSSQ)

ˆ

 

Press the 

CHANNEL

 selector knob, then select the squelch hysteresis level

using the 

CHANNEL

 selector knob.

ˆ

 

Next, press the 

CHANNEL

 selector knob.

ˆ

 

Rotate the 

CHANNEL

 selector knob to select the next setting.

€

 

Squelch Threshold Adjustment (THSQ)

ˆ

 

Inject a –9 dBµ (0.35 µV) RF signal (with a standard modulation: 30 % AM
modulation @ 1 kHz), then press the 

CHANNEL

 selector knob 

twice

.

ˆ

 

Now rotate the 

CHANNEL

 selector knob to select the next setting.

Summary of Contents for VXA-150

Page 1: ...ould any alignment be attempted unless the normal function and operation of the transceiver are clearly understood the cause of the malfunction has been clearly pinpointed and any faulty components replaced and realignment determined to be absolutely necessary Problems caused by unauthorized attempts at realignment are not covered by the warranty policy Vertex Standard reserves the right to change...

Page 2: ...is required If not remove the test equipment except dummy load and wattmeter if connected before proceeding Correct alignment requires that the ambient temperature be the same as that of the transceiver and test equipment and that this temperature be held constant between 20 30 C 68 86 F When the transceiver is brought into the shop from hot or cold air it should be allowed some time to come to ro...

Page 3: ...ernal System Alignment Routine Internal System Alignment Routine Internal System Alignment Routine This feature uses a programmed routine in the transceiver which replaces many previously complex discrete component settings and adjustments with digitally controlled settings via the CHANNEL selector knob Transceiver adjustments include Squelch Hysteresis Adjustment Squelch Threshold Adjustment Sque...

Page 4: ...and hold the in the CHANNEL selector knob for 2 second to save all setting and exit Resetting the CPU Resetting the CPU Resetting the CPU Resetting the CPU If you are unable to gain control of the transceiver or if you want to clear all memories and settings to their factory defaults press and holding the MONITOR button and PTT switch while turning the transceiver on ...

Reviews: