Power Connection
Operation of the VX-4500/-4600 transceiver from an AC line requires a power
supply capable of providing at least 10 Amps (for 25 W model) or 15 Amps (for
45 W/50 W models) continuously at 13.6 Volts DC. Please contact your dealer to
select an optimal power supply that satisfy these requirements.
Use the supplied DC power cable for making power connections to the power
supply. Connect the
RED
power cable lead to the
POSITIVE
(+) power supply
terminal, and connect the
BLACK
power cable lead to the
NEGATIVE
(–) power
supply terminal.
Antenna Installation
When used the VX-4500/-4600 transceiver as a base station, the antenna installa-
tion must comply with the following requirements in order to ensure optimal per-
formance and compliance with the RF energy exposure limits in the standards and
guidelines.
The antenna should be mounted outside the building on the roof or a tower if
at all possible.
As with all fixed site antenna installations, it is the responsibility of the licens-
ee to manage the site in accordance with applicable regulatory requirements
and may require additional compliance actions such as site survey measure-
ments, signage, and site access restrictions in order to insure that exposure
limits are not exceeded.
RED: POSITIVE
(
+
)
Terminal
BLACK: NEGATIVE
(
–
)
terminal
AC Power Supply
(13.6 V, 10A or 15 A)
Antenna