20
Set the transceiver to CH#2 via the "Channel" box
located upper right corner on the "Alignment"
window previously.
Set the SG output level to 0dBµ EMF with 1.5
kHz deviation.
To adjustment click the left mouse button on the
"
Tight noise SQL
" then "
Start
" button.
Press "OK" to lock in the new data.
Threshold Noise SQL
This parameter is used to Threshold noise SQL.
Set the transceiver to CH#1 via the "Channel" box
located upper right corner on the "Alignment"
window previously.
Set the SG output level to -7dBµ EMF with 3kHz
deviation.
To adjustment click the left mouse button on the
"
Threshold noise SQL
" then "
Start
" button.
Press "OK" to lock in the new data.
Alignment