17
Alignment
Move the Slide bar, as needed, to set the Max
Deviation (Wide) to the following specification,
as indicated on the deviation meter.
Max Deviation (Wide): 2.8[kHz](±0.1[kHz])
When the desired deviation level is attained,
press "OK" to lock in the new data.
Set the transceiver to CH#2, and set the Max De-
viation (Narrow) to the following specification,
as indicated on the deviation meter.
Max Deviation (Narrow): 1.4[kHz](±0.1[kHz])
When the desired deviation level is attained,
press "OK" to lock in the new data.
Modulation balance
This parameter is used to align Modulation balance.
Set the transceiver to CH#1 via the "Channel" box
located upper right corner on the "Alignment"
window previously.
To adjustment click the left mouse button on the
"
Modulation balance
" then "
Start
" button.
Move the Slide bar, as needed, to set the modula-
tion (Wide) wave as follows.
When the desired the modulation wave is at-
tained, press "OK" to lock in the new data.
Set the transceiver to CH#2, and set the modula-
tion (Narrow) wave as follows.
When the desired deviation level is attained,
press "OK" to lock in the new data.
OK
NG
NG
Adjust the AF generator output level to
774mVrms(0dBm) at 300Hz to the pin3 of the
J1502 (D-sub 9pin).
Summary of Contents for VX-2500U
Page 5: ...5 Block Diagram 1 ...
Page 6: ...6 Block Diagram 2 ...
Page 7: ...7 Block Diagram 3 ...
Page 8: ...8 Block Diagram 4 ...
Page 9: ...9 Interconnection Diagram ...
Page 10: ...10 Note ...
Page 22: ...22 Note ...
Page 29: ...29 Circuit Diagram 1 RF Unit Ver D Lot 6 ...
Page 30: ...30 Circuit Diagram 2 RF Unit Ver D Lot 6 ...
Page 43: ...RF 1 Unit Ver CS1 43 Circuit Diagram 1 ...
Page 44: ...RF 1 Unit Ver CS1 44 Circuit Diagram 2 ...
Page 57: ...RF 2 Unit Ver DS1 57 Circuit Diagram 1 ...
Page 58: ...RF 2 Unit Ver DS1 58 Circuit Diagram 2 ...
Page 69: ...PANEL Unit 69 Circuit Diagram ...
Page 70: ...PANEL Unit 70 Note ...
Page 78: ...78 Panel Unit Note ...