VX-110 O
PERATING
M
ANUAL
32
Item #
35
36
Menu Item
BATT
SKIP
Function
Indication of the Supply Voltage
Enable/Disable skipping of a memory during
scanning
Available Values
–
ON/OFF
Default
–
–
Ú
Depends on the transceiver version
Set Mode Details
Set Item 1 [ALPHA]
Function: Store Alpha-Numeric “Tags” for the Memory channels.
See page 19 for details.
Set Item 2 [ARS]
Function: Enable/disable the Automatic Repeater Shift function.
Available Values: ON/OFF
Default: ON
Set Item 3 [RPT]
Function: Set the Repeater Shift Direction
Available Values: -RPT/SIMP/+RPT
Default: SIMP
Set Item 4 [SHIFT]
Function: Set the magnitude of the Repeater Shift.
Available Values: 0.00 ~ 99.9 MHz
Default: Depends on the transceiver version, as well as the setting of Menu #2 (ARS).
Set Item 5 [STEP]
Function: Setting of the synthesizer steps.
Available Values: 5/10/12.5/15/20/25/50 kHz
Default: Depends on the transceiver version.
Set Item 6 [RESUME]
Function: Select the Scan Resume mode.
Available Values: 5 SEC/BUSY/HOLD
Default: 5 SEC
Set Item 7 [SCN LMP]
Function: Enable/disable the Scan lamp while paused.
Available Values: ON/OFF
Default: ON
Set Item 8 [RX SAVE]
Function: Select the Receive-mode Battery Saver interval (“Sleep” ratio).
Available Values: OFF/200ms(1:1)/300ms(1:1.5)/500ms(1:2.5)/1s(1:5)/2s(1:10)
Default: 200ms(1:1)
Set Mode