System Features
10
VL-MPEu-C1E Hardware Reference Manual
The table below provides information about the function, mating connectors, and transition cables
for VL-MPEu-C1E connectors.
Table 1: Connector Functions and Interface Cables
Connector
Function
Transition Cable
Cable Description
J1
CAN Port
VL-CBR-0603 (Molex 51065-
0600)
CAN bus cable, two channels, 2 mm 6-
pin MicroClasp to 2x DB9 connector,
0.5 m
Note:
J1 header part number = Molex 53254-0670
CAN
T
ERMINATION
J
UMPERS
Two 2mm jumpers are required per CAN interface due to the split termination (V1 dual jumper
for CAN Port 0 and V2 dual-jumper for CAN Port 1). The jumpers are installed to enable split-
termination. The following are the jumper states for the V1 positions on Port 0 and V2 jumper on
Port 1.
Table 2: CAN Termination Jumpers (CAN Port 0)
Jumper Block(s)
Description
V1[1-3] and V1[2-4]
Split Termination (both must be installed)
V1[1-2]
Non-Split Termination
V1[3-4]
Holding Position only (no function)
No Jumpers
No termination
Table 3: CAN Termination Jumpers (CAN Port 1)
Jumper Block(s)
Description
V2[1-3] and V2[2-4]
Split Termination (both must be installed)
V2[1-2]
Non-Split Termination
V2[3-4]
Holding Position only (no function)
No Jumpers
No termination
Note:
The jumpers can be removed and bypassed (using 0-ohm 0402 resistors) for jumper-less
operation. The split termination capacitor can be removed if split-termination is not desired.