122051C VERSATILE DEEP CLEANER 115V
3
Legend Brands, Inc.
CLEANING
7.
Pretreat soiled area (optional).
Apply spot cleaning
or other prespray solution directly and let it dwell on
cleaning surface per chemical label.
8.
Rinse extraction.
Rinse with plain water solution and
extract thoroughly.
9.
Dry completely.
Accelerate drying with warm air
temperatures and airmovers.
Cleaning Tips:
•
Test surfaces first for colorfastness.
•
Clean small sections at a time. If using prespray,
don’t let it dry on surfaces.
•
Don’t over-wet. Always extract thoroughly.
OPERATION
10. Turn on Blower and Pump/Heater.
11. Wait for heated solution to reach hand tool, then
begin cleaning (see CLEANING above).
Empty/refill tanks
NOTICE:
When cleaning solution is used up, 1) empty
recovery tank and 2) refill solution tank.
1. Empty recovery tank.
a) Switch off blower and heater.
b) With vacuum hose still attached, lift vacuum hose
vertically to drain any water in hose into recovery
tank.
c) Remove vacuum hose from recovery tank.
d) Release twist latch, slide recovery tank forward and
lift up. Keep vacuum inlet tipped upward to avoid
drips from the vacuum intake.
e) While holding the tank upright, remove tank cap
f) Pour into a suitable drain, such as a toilet or utility
sink.
2. Refill solution tank
(see SETUP steps 3 and 4) when
emptying recovery tank or when no solution flows from
spray nozzle.
3. Resume cleaning.
MAINTENANCE
WARNING: Unplug machine before servicing.
Possibility of electrical shock.
WARNING: Interior components may be hot
after operation. Let unit cool completely
before servicing.
DAILY OR AFTER EACH USE
Rinse solution tank
with clear water to ensure no
detergents or rinse agents remain in the tank.
Clean strainer cup and float ring.
Remove solution
tank cover, lift out assemblies and rinse clean. Allow
assemblies to air dry before reinstallation.
Rinse recovery tank
with clean water. Helps to prevent
damaging deposits and reduces the growth of odor-
causing bacteria.
Wipe exterior
with damp cloth.
Reassemble unit and turn on blower motor ONLY
and run for 2 minutes to remove remaining moisture
from the blower.
Release water pressure with accessory tool spray
control lever, then disconnect vacuum hose and
solution hose.
Coil for storage.
Coil power cord and secure with strap
for transport
and storage.
AS NEEDED
To restore exterior shine,
use an automotive vinyl
cleaner/protectant product.
CONTACT
Legend Brands
15180 Josh Wilson Road
Burlington, WA 98233
800-932-3030 [email protected]
VDC.CleanerLivingProducts.com
SPECIFICATIONS
Model
108779
Capacity
Solution tank: 2.5 gal. | 9.5 L
Recovery tank: 2.0 gal. | 7.6 L
Vacuum lift
4.5 in. | 114.3 mm Hg
Solution spray pressure 58 PSI | 400 kPa
Solution spray flow
0.18 GPM | 0.68 LPM
Dimensions
(H × L × W)
22.4 × 26.0 ×11.1 in.
56.9 × 66.0 × 28.2 cm
Weight
34.6 lbs. | 15.7 kg (without hose and tool)
Amps
Pump: 0.5A Vacuum: 7.0A Heater: 6.0A
Total: 13.5A
Volts
115V
Frequency
60 Hz
Power (full)
1.55 KW
Operating range
33°F–100°F | 1°C–38°C
Sound level
53 dB
Construction
Rotomolded polyethylene housing
Power cord
25 ft. | 7.6 m