background image

 

122051C VERSATILE DEEP CLEANER 115V 

Legend Brands, Inc. 

CLEANING  

7. 

Pretreat soiled area (optional).

 Apply spot cleaning 

or other prespray solution directly and let it dwell on 

cleaning surface per chemical label.  

8. 

Rinse extraction.

 Rinse with plain water solution and 

extract thoroughly. 

9. 

Dry completely.

 Accelerate drying with warm air 

temperatures and airmovers. 

Cleaning Tips: 

  Test surfaces first for colorfastness.  

  Clean small sections at a time. If using prespray, 

don’t let it dry on surfaces.  

  Don’t over-wet. Always extract thoroughly. 

OPERATION 

10. Turn on Blower and Pump/Heater.   
11. Wait for heated solution to reach hand tool, then 

begin cleaning (see CLEANING above). 

Empty/refill tanks 

NOTICE:

 When cleaning solution is used up, 1) empty 

recovery tank and 2) refill solution tank.  

1. Empty recovery tank.  

a)  Switch off blower and heater.  

b)  With vacuum hose still attached, lift vacuum hose 

vertically to drain any water in hose into recovery 

tank.  

c)  Remove vacuum hose from recovery tank.  

d)  Release twist latch, slide recovery tank forward and 

lift up. Keep vacuum inlet tipped upward to avoid 

drips from the vacuum intake.  

e)  While holding the tank upright, remove tank cap  

f)  Pour into a suitable drain, such as a toilet or utility 

sink.  

2. Refill solution tank

 (see SETUP steps 3 and 4) when 

emptying recovery tank or when no solution flows from 

spray nozzle.  

3. Resume cleaning.  

MAINTENANCE 

WARNING: Unplug machine before servicing. 

Possibility of electrical shock.  

WARNING: Interior components may be hot 

after operation. Let unit cool completely 

before servicing.  

DAILY OR AFTER EACH USE 

Rinse solution tank

 with clear water to ensure no 

detergents or rinse agents remain in the tank. 

Clean strainer cup and float ring. 

Remove solution 

tank cover, lift out assemblies and rinse clean. Allow 

assemblies to air dry before reinstallation. 

 

Rinse recovery tank 

with clean water. Helps to prevent 

damaging deposits and reduces the growth of odor-

causing bacteria.  

Wipe exterior 

with damp cloth.  

Reassemble unit and turn on blower motor ONLY

 

and run for 2 minutes to remove remaining moisture 

from the blower. 

Release water pressure with accessory tool spray 

control lever, then disconnect vacuum hose and 

solution hose. 

Coil for storage. 

Coil power cord and secure with strap

 for transport 

and storage.  

AS NEEDED  

To restore exterior shine, 

use an automotive vinyl 

cleaner/protectant product.

 

CONTACT 

Legend Brands 

15180 Josh Wilson Road 

Burlington, WA 98233  

800-932-3030 [email protected] 

VDC.CleanerLivingProducts.com 

SPECIFICATIONS 

Model 

108779 

Capacity 

Solution tank: 2.5 gal. | 9.5 L  

Recovery tank: 2.0 gal. | 7.6 L 

Vacuum lift 

4.5 in. | 114.3 mm Hg 

Solution spray pressure   58 PSI | 400 kPa  
Solution spray flow 

0.18 GPM | 0.68 LPM 

Dimensions  

(H × L × W) 

22.4 × 26.0 ×11.1 in.  

56.9 × 66.0 × 28.2 cm 

Weight 

34.6 lbs. | 15.7 kg (without hose and tool) 

Amps 

Pump: 0.5A  Vacuum: 7.0A  Heater: 6.0A  

Total: 13.5A 

Volts 

115V 

Frequency 

60 Hz 

Power (full) 

1.55 KW 

Operating range 

33°F–100°F | 1°C–38°C 

Sound level 

53 dB 

Construction 

Rotomolded polyethylene housing 

Power cord 

25 ft. | 7.6 m 

 

 

 

Summary of Contents for 108779

Page 1: ...aged cord or plug If appliance is not working as it should has been dropped or damaged return it to an authorized service center for repair Do not leave machine unattended when plugged in Unplug cord...

Page 2: ...ian using only parts approved by Legend Brands GROUNDING INSTRUCTIONS WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified ele...

Page 3: ...ng Possibility of electrical shock WARNING Interior components may be hot after operation Let unit cool completely before servicing DAILY OR AFTER EACH USE Rinse solution tank with clear water to ensu...

Page 4: ...e si se ha ca do o da ado devu lvalo a un centro de servicio autorizado para su reparaci n No deje la m quina sin atenci n cuando est enchufada Desenchufe el cable del tomacorriente cuando no est en u...

Page 5: ...a aspiradora en l quido No use como aspiradora en seco Las part culas de polvo da ar n los motores de la aspiradora El da o causado por la aspiraci n en seco anular la garant a Para prevenir el crecim...

Page 6: ...la manguera de la aspiradora a n colocada levante la aspiradora verticalmente para drenar el agua en la manguera hacia el tanque de recuperaci n c Retire la manguera de la aspiradora del tanque de re...

Page 7: ...ac o 4 5 pulg 114 3 mm Hg Presi n de pulverizaci n de la soluci n 58 PSI 400 kPa Flujo de pulverizaci n de la soluci n 0 18 GPM 0 68 LPM Dimensiones Alto Prof Ancho 22 4 26 0 11 1 pulg 56 9 66 0 28 2...

Page 8: ...pas utiliser avec un adaptateur Ne pas utiliser avec des rallonges Ne pas utiliser avec un cordon ou une fiche endommag s Si l appareil ne fonctionne pas comme il le devrait s il est tomb ou a t endo...

Page 9: ...ion avec de l eau dure pourrait entra ner la formation de d p ts min raux l int rieur des pompes et des raccords Les dommages caus s par des d p ts min raux annuleront la garantie Renseignez vous aupr...

Page 10: ...commencez le nettoyage voir NETTOYAGE ci dessus Vider remplir les r servoirs AVIS Lorsque la solution de nettoyage est puis e 1 videz le r servoir de r cup ration et 2 remplissez le r servoir de solu...

Page 11: ...s com VDC CleanerLivingProducts com CARACT RISTIQUES Mod le 108779 Capacit R servoir de solution 2 5 gal 9 5 L R servoir de r cup ration 2 0 gal 7 6 L Port e de l aspirateur 4 5 po 114 3 mm Hg Pressio...

Reviews: