Versa Networks CSG700 Series Hardware Manual Download Page 21

Compatibility Issues

• Link flap issues may occur if the remote device is an older Cisco Nexus 3064 switch (2012).

• After you reboot CSG700 appliances, the link error "DCX-NO Ack in 100 PDUs" may occur on Cisco Nexus

switches. As a workaround, issue the

shutdown

command followed by a

no shutdown

on the Cisco switch

interface that is used for link detection.

• BASE-T SFP modules for Denverton-based boards are not supported.

Installation Guidelines

This article provides general safety standards and warnings relating to installing or connecting a CSG700 series
appliance.

General Safety Guidelines

Caution: Before installing or removing a CSG700 series appliance, ensure that the appliance chassis is electrically
connected to ground. When you are installing or removing an appliance, ensure that you wear an ESD grounding wrist
strap. To put the ESD grounding strap on properly, attach it to an ESD point and then place the other end of the strap
around your bare wrist, making good skin contact. Failure to use an ESD grounding strap could damage the appliance.

• Install the CSG700 series appliance in compliance with the following local, national, and international electrical

codes:

• United States—National Fire Protection Association (NFPA 70), United States National Electrical Code.

• Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7.

• Evaluated to the TN power system.

• Canada—Canadian Electrical Code, Part 1, CSA C22.1.

• Locate the emergency power-off switch in the installation area. In case of an electrical accident, turn off the power

quickly.

• Disconnect power to the appliance before installing or removing it.

• Disconnect power from the circuit that is being used for the appliance.

• If hazardous conditions exist, do not work alone.

• If you are working under conditions that might be hazardous to the eyes, wear safety glasses or goggles.

Federal Communication Commission Interference Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device

 

may not cause harmful interference, and (2) this device must accept any interference received, including interference

 

that may cause undesired operation.

https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_700_Series/Complete_CSG700_Series_Hardware_Gui…
Updated: Tue, 18 Oct 2022 06:10:27 GMT
Copyright © 2021, Versa Networks, Inc.

22

Summary of Contents for CSG700 Series

Page 1: ...lable if a Network Interface Card NIC module is installed MDI and MDIX autoswitchable EoC ports Two USB ports for plugging in external LTE or WiFi modems PoE source support on four Ethernet ports Two...

Page 2: ...ance with the SIM slots and two LEDs for status and power This is the side that is visible when you install the appliance in an office environment The rear panel has the power and reset buttons and va...

Page 3: ...port 1 Memory DDR4 ECC DRAM CSG730 4 GB CSG750 8 GB CSG770 16 GB Disk 1 SSD M 2 SATA based 1 Disk 1 SSD default size CSG730 32 GB CSG750 64 GB CSG770 128 GB Disk 2 and Disk 3 USB based Flexible Power...

Page 4: ...for CSG750 and CSG770 appliances Humidity 10 to 85 relative humidity Altitude Maximum 3000 m 10000 ft Noise level 0 dBm Storage Conditions Temperature 20 to 70 C 4 to 158 F at sea level Humidity 10 t...

Page 5: ...he following 4GP 120W 4DS 4GF 8GE 1VA Regulatory Compliance Table 2 lists the regulatory compliance specifications for a CSG700 series chassis Table 2 CSG700 Series Regulatory Compliance Specification...

Page 6: ...2019 11 Class A EN 301 489 17 V3 1 1 2017 02 Draft EN 301 489 52 V1 1 0 2016 11 EN 301 893 V2 1 1 2017 05 EN 301 893 19 V2 1 1 2019 04 EN 300 328 V2 1 1 2016 11 EN 301 908 1 V11 1 1 2016 07 EN 55032 2...

Page 7: ...nd decryption 5A002U 8542310001 G156910L1 CSG700 series appliance Front and Rear Panel Components This article describes the front and rear panel components of a CSG700 series appliance For the exact...

Page 8: ...If you subscribe to a single wireless service use the SIM 1 slot to install the LTE device If you are subscribing to dual wireless service use both the SIM 1 and SIM 2 slots to activate the LTE device...

Page 9: ...is booting LTE White Off LTE module not installed or not connected Solid white LTE module is up and running Blinking white LTE module is connecting Bluetooth Blue Off Bluetooth module is not installed...

Page 10: ...equest system reset CLI command Reset the Appliance to the Factory Default Configuration from the CLI You can reset the appliance to the factory default configuration from the CLI You can connect to t...

Page 11: ...tated is Running process 5625 versa addrmgrd is Running process 5857 versa rt cli xfm is Running process 5798 versa rtd is Running process 5827 versa dhcpd is Running process 5620 versa eventd is Runn...

Page 12: ...on devices when the serial number is not mandated for the zero touch provisioning ZTP process Additional Information Factory Default Settings for Branch Devices Network Interface Cards The Cloud Servi...

Page 13: ...Gigabit Ethernet copper Supports 10 100 1000BASE T ADSL VDSL NIC 1VA 1 RJ45 port ADSL VDSL Annex A Single port ADSL VDSL module that supports Annex A POTS NIC 1VB 1 RJ45 port ADSL VDSL Annex B Single...

Page 14: ...SFP Combination Port NIC Specifications Table 3 lists the NIC specifications for a CSG700 series chassis Table 3 CSG700 Series NIC Specifications Item Specification Item Specification Typical power co...

Page 15: ...epth 9 228 6 mm Package weight 0 77 lb 350 gm Operating Conditions Temperature 0 to 40 C 32 to 104 F Humidity 10 to 85 relative humidity Altitude Maximum 3000 m 10000 ft Noise level 0 dBm Storage Cond...

Page 16: ...nectivity by preventing unauthorized code on target devices The LTE modem connections are metered connections and the Versa software implementation ensures that the LTE service is charged only when ne...

Page 17: ...ance unplug the power cable plug the power cable back in and press the power button Simply powering the appliance on and off does not restart the LTE modem Also pressing the reset button on the applia...

Page 18: ...es including over the air traffic analysis and other analytics The VOS software provides queuing mechanisms including weighted round robin WRR In addition the WiFi AP module has a built in QoS feature...

Page 19: ...you allow 1 RU space above the appliance for cooling When placing a CSG700 series appliance on a desk ensure that the vents on the top of the unit are never blocked to allow hot air to flow out of the...

Page 20: ...Ensure that you have enabled the 1 Gigabit Ethernet interface in the Versa Operating SystemTM VOSTM software For 1 Gigabit Ethernet SFPs you must turn off autonegotiation on the remote device and you...

Page 21: ...ce in compliance with the following local national and international electrical codes United States National Fire Protection Association NFPA 70 United States National Electrical Code Other countries...

Page 22: ...cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device L metteur r cepteur exempt de licence contenu dans le pr sent appa...

Page 23: ...st sup rieur au gain maximal indiqu pour tout type figurant sur la liste sont strictement interdits pour l exploitation de l metteur LTE MC7455 modules Radio metteur IC 2417C MC7455 Gain d antenne 4 1...

Page 24: ...ing a CSG700 series appliance follow the guidelines and requirements listed in this article Site Preparation Guidelines Install the appliance in an enclosed and secure environment and allow only autho...

Page 25: ...planning your site for installing a CSG700 series appliance in a 19 inch rack allow a minimum of 0 5 RU space above the appliance to allow hot air to flow out of the appliance However itt is recommend...

Page 26: ...ssory box and the appliance from the foam packing material 4 Remove the accessories from the accessories box 5 Verify the components against the packing list that is included in the box Figure 1 Unpac...

Page 27: ...king List for a CSG700 Series Appliance The cardboard carton in which a CSG700 series appliance is shipped contains a packing list Check the packing list against the parts that you receive in the ship...

Page 28: ...ars 2 Screws for rack mounting ears 6 size M4 Screws for rack mounting 4 size M6 Mount a CSG700 Series Appliance in a Rack You can mount a CSG700 series appliance in a 19 inch rack To mount the applia...

Page 29: ...Do not overtighten the screws Figure 3 Attach the Mounting Ears to a CSG700 Series Appliance 5 Grasp both sides of the appliance chassis making sure that the front of the chassis is facing you 6 Stan...

Page 30: ...article describes how to connect a CSG700 series appliance to an AC power source and to a management console Versa recommends an uninterruptible power strategy that prevents power interruptions A UPS...

Page 31: ...ate local plug To connect a CSG700 series appliance to an AC power source 1 Attach one end of the ESD grounding strap to your bare wrist and connect the other end to the ESD point on the rack 2 Plug o...

Page 32: ...the connection use the following default console port settings Speed baud 115200 Data bits 8 Stop bits 1 Parity None Flow control None To connect a management console to a CSG700 series appliance 1 Op...

Page 33: ...n Serial The Options Controlling Local Serial Lines page displays https docs versa networks com Hardware Cloud_Services_Gateway_700_Series Complete_CSG700_Series_Hardware_Gui Updated Tue 18 Oct 2022 0...

Page 34: ...OM port that your device is connected to The default COM port is COM1 https docs versa networks com Hardware Cloud_Services_Gateway_700_Series Complete_CSG700_Series_Hardware_Gui Updated Tue 18 Oct 20...

Page 35: ...Line section enter the following information https docs versa networks com Hardware Cloud_Services_Gateway_700_Series Complete_CSG700_Series_Hardware_Gui Updated Tue 18 Oct 2022 06 10 27 GMT Copyrigh...

Page 36: ...ecommended value is 1 d In the Parity field select None This is the method of detecting errors in transmission e In the Flow Control field select None This is the method of preventing data overflow 6...

Page 37: ...To open the session click Open https docs versa networks com Hardware Cloud_Services_Gateway_700_Series Complete_CSG700_Series_Hardware_Gui Updated Tue 18 Oct 2022 06 10 27 GMT Copyright 2021 Versa N...

Page 38: ...ith the username admin and the password versa123 https docs versa networks com Hardware Cloud_Services_Gateway_700_Series Complete_CSG700_Series_Hardware_Gui Updated Tue 18 Oct 2022 06 10 27 GMT Copyr...

Page 39: ...ith an RJ 45 connector To connect a CSG700 series appliance to a management console 1 Plug one end of the console cable into the console port located on the rear panel of the CSG700 series appliance 2...

Reviews: