Type
Manufacturer
Part Number
Transceiver Description
reach (LR)
industrial operating temperature
Compatible Remote Switches
The following switches have been tested with a 1-Gigabit Ethernet link connection to CSG700 series appliances:
• Cisco Nexus 3048T
• Dell S3048 and S4128F
• Juniper EX2200
Connection Recommendations
The following are recommendations for connecting at 1-Gigabit Ethernet speeds:
• After you dynamically insert an SFP or change the SFP speed, you must disable and then reenable the VNI
interface on the CSG700 appliance.
• If the configuration on the remote device changes, you must disable and then re-enable the VNI interface on the
CSG700 appliance.
• Ensure that you have enabled the 1-Gigabit Ethernet interface in the Versa Operating System
TM
(VOS
TM
) software.
• For 1-Gigabit Ethernet SFPs, you must turn off autonegotiation on the remote device, and you must set the
connection speed 1-GE. For example, for Cisco switches, in the interface configuration, configure the speed to
1000:
interface Ethernet 1/25
speed 1000
For Juniper switches, configure no-auto-negotiation on the interface:
enable;
ether-options {
no-auto-negotiation;
link-mode full-duplex;
speed {
1g;
}
}
Note: Before you order units in bulk, validate connections with the target remote device in a lab or testing environment to
ensure that there are no compatibility or link issues.
https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_700_Series/Complete_CSG700_Series_Hardware_Gui…
Updated: Tue, 18 Oct 2022 06:10:27 GMT
Copyright © 2021, Versa Networks, Inc.
21