background image

13

Gas supply line

Shutoff valve

“open” position

To range

Fig. 2.1

All gas connections must be made according to national and local codes. This 

gas supply (service) line must be the same size or greater than the inlet line of the 

appliance. Sealant on all pipe joints must be resistant to te action of LP/Propane gas.

The range is equipped for the use with NATURAL gas. It is design-certified by CSA 

International for NATURAL and L.P. gases with appropriate conversion.
The model/serial rating plate, located on the inner side of the storage compartment 

pivoting panel, has information on the type of gas that can be used. If this information 

does not agree with the type of gas available, check with the local gas supplier. See 

page from 19 to 21 for L.P. gas conversion inctructions.

1. Manual Shut-off Valve 

(fig. 2.1)

:

A manual shut-off valve must be installed in an accessible location in the gas line 

external to the appliance for the purpose of turning on or shutting off gas to the 

appliance (In Massachusetts such shutoff devices should be approved by the Board 

of State Examiners of Plumbers & Gas Fitters). This valve should be located in the 

same room as the range and should be in a location that allows ease of opening and 

closing (in a position where it can be reached quickly in the event of an emergency).
Do not block access to the shutoff valve. The valve is for turning on or shutting off 

gas to the appliance.

2. Pressure Regulator:

a)   All heavy duty, commercial type cooking equipment must have a pressure regulator 

on the incoming service line for safe and efficient operation, since service pressure 

may fluctuate with local demand. 

  Before installing the regulator mount the 1/2” NPT (conical) male connector to the 

regulator (see picture 2.2a). Gasket supplied have to be placed between 1/2” NPT 

(conical) connector/extension pipe male pipe fitting (see picture 2.2b).

  The regulator supplied with this range must be installed before any gas connections 

are made.

  Use supplied pressure regulator only.  

b) Assemble the extension pipe + pressure regulator group to the range manifold 

interposing the gasket supplied.

gas connection

Explosion Hazard

Use a new CSA or UL approved 
gas supply line.
Install a shut-off valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14” water 
column.
Examples of a qualified person 
include licensed heating per-
sonnel, authorized gas compa-
ny personnel, and authorized 
service personnel.
Failure to do so can result in 
death, explosion, or fire.

Summary of Contents for VEFSGE 365 Series

Page 1: ...3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable the Standard for Manufactured Home Installations ANSI NCSBCS A...

Page 2: ...ighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency...

Page 3: ...f domestic household food and in not suitable for any none domestic application and therefore should not be used in a commercial environmement The appliance guarantee will be void if the appliance is...

Page 4: ...lified installer service agent or the gas supplier IMPORTANT The use of suitable protective clothing gloves is recommended when handling installing of this appliance INSTALLATION INSTRUCTIONS TOOLS NE...

Page 5: ...ly remove the range by pulling outward CAUTION Range is heavy use care in handling 10 Electrical Requirement Electrical installation should comply with national and local codes 11 Air Supply and Venti...

Page 6: ...X 37 13 32 950 mm Fig 1 1a Fig 1 1b 2 The range CANNOT be installed directly adjacent to side walls tall cabinets tall appliances or other side vertical surfaces above 36 914 mm high There must be a m...

Page 7: ...Dotted line showing the position of the range when installed Depending on feet regulation Area for GAS connection Area for ELECTRICAL connection Fig 1 2 Rif inch mm A 7 15 32 190 B 17 15 16 455 5 C 6...

Page 8: ...mm 0 0 mm 20 min 500 mm 11 13 16 min 300 mm 13 max 330 mm 457 mm 18 min 30 min 762 mm 914 mm 36 0 0 0 mm 0 mm 20 min 500 mm 11 13 16 min 300 mm 13 max 330 mm OVEN VENT OVEN VENT Fig 1 3b Fig 1 3a PROX...

Page 9: ...SLAND TRIM 457 mm 18 min 30 min 762 mm 914 mm 36 0 0 0 mm 0 mm 20 min 500 mm 13 max 330 mm 11 13 16 min 300 mm 12 min 305 mm 457 mm 18 min 30 min 762 mm 914 mm 36 0 0 mm 0 0 mm 20 min 500 mm 11 13 16...

Page 10: ...Fig 1 5 LEVELLING THE COOKER The cooker may be levelled by screwing the lower ends of the feet IN or OUT fig 1 6 It is important to observe the directions of figure 1 6 1 31 32 50 mm 0 mm 0 Fig 1 6 F...

Page 11: ...to install the backguard or the island trim Assemble the backguard or the island trim as shown in figure 1 8 or 1 9 and fix it by screw ing the 5 screws A which are already fixed on the back of the co...

Page 12: ...t slide range into place Be sure the anti tip bracket is fully inserted in the slot of the range back 26 11 16 678 mm from top of cooktop with range installed in final position 455 5 mm 17 15 16 455 5...

Page 13: ...ould be in a location that allows ease of opening and closing in a position where it can be reached quickly in the event of an emergency Do not block access to the shutoff valve The valve is for turni...

Page 14: ...asket supplied The regulator cover must be ordiented toward the front side of the range IMPORTANT use two spanners to tighten the connection Regulator cover Fig 2 2a Fig 2 2b STEP 1 Mount the 1 2 NPT...

Page 15: ...e A bracket STEP 4 Assemble the extension pipe pressure regulator group to the range manifold interposing the gasket supplied The regulator cover must be ordiented toward the front side of the range I...

Page 16: ...16 B B STEP 5 Fix the B bracket on the back of the range by the 2 two screws supplied with the kit for gas connection The regulator cover must be ordiented toward the front side of the range Fig 2 2e...

Page 17: ...e manifold Manifold male pipe fitting 1 2 G cylindrical ISO 228 1 male Extension pipe female pipe fitting 1 2 G cylindrical ISO 228 1 female Gasket Extension pipe Extension pipe female pipe fitting Ar...

Page 18: ...that system at pressures in excess of 1 2 PSI 3 5 kPa g The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of...

Page 19: ...RS TABLE The nozzle diameters expressed in hundredths of a millimetre are marked on the body of each injector SETTING THE PRESSURE REGULATOR fig 2 5 The pressure regulator is accessible through the st...

Page 20: ...g burner DUAL burner BURNERS NOMINAL POWER BTU hr REDUCED POWER BTU hr LP PROPANE 11 W C P NATURAL GAS 4 W C P injector 1 100 mm injector 1 100 mm Semi rapid R 6000 1500 72 118 Triple ring TC 12000 50...

Page 21: ...the knob With a thin screwdriver turn the screw F until adjustment is correct fig 2 7 Inside crown of DUAL burner Light the DUAL burner Set the gas valve to position Remove the knob Using a screwdrive...

Page 22: ...Allow two to three feet of slack in the line so that it can be moved if servicing is ever necessary ELECTRICAL CONNECTION WITH POWER CORD Use a 3 wire power supply cord kit rated for 30 amps 125 250...

Page 23: ...r Cord through the hole in the Power Cord Bracket then tighten the Power Cord by using a suitable Strain Relief Allow enough slack to easily attach the cord terminals to the Terminal Block 3 Remove th...

Page 24: ...range by unscrewing the 6 fixing Screws fig 3 1 2 Feed 1 2 1 3 cm trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp 3 Remove the 3 wire...

Page 25: ...AGRAM KEY PR Electronic programmer E61 Relay P E61 Relay contact P PR Programmer contact CF Cooling fan P1 8 Oven switch contact AS Air flow switch OF Oven fan TPL Thermostat pilot lamp CE Circular el...

Page 26: ...26...

Page 27: ...27...

Page 28: ...anscription errors in the present booklet The manufacturer re serves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and withou...