Verona VDGCT212F Series Installation Instructions Manual Download Page 1

BUILT-IN GAS COOKTOPS

for residential use only

THIS COOKTOP IS FOR RESIDENTIAL USE ONLY

Models:

  

VDGCT212F..

  VDGCT424FSS
  VDGCT530FSS
  VDGCT536FSS

INSTALLATION INSTRUCTIONS
IMPORTANT - PLEASE READ AND FOLLOW

•  Before beginning, please read these instructions completely and carefully.

•  Do not remove permanently affixed labels, warnings, or plates from the product. This may 

void the warranty.

•  Please observe all local and national codes and ordinances.

•  Please ensure that this product is properly grounded.

•  The electrical plug should always be accessible.

• 

The installer should leave these instructions with the consumer who should retain 
for local inspector’s use and for future reference.

Installation must conform with local codes or in the absence of codes, the National Fuel Gas 

Code ANSI Z223.1/NFPA 54 - Iatest edition. Electrical installation must be in accordance with 

the National Electrical Code, ANSI/NFPA70 - latest edition and/or local codes.

IN CANADA: Installation must be in accordance with the current CAN/CGA-B149.1 National 

Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.

Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical 

Codes Part 1 and/or local codes.
INSTALLATION IN MANUFACTURED (MOBILE) HOME: The installation must conform with 

the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly 

the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, 

when such standard is not applicable, the Standard for Manufactured Home Installations, 

ANSI/NCSBCS A225.1, or with local codes where applicable.
INSTALLATION IN RECREATIONAL PARK TRAILERS: The installation must conform with 

state or other codes or, in the absence of such codes, with the Standard for Recreational Park 

Trailers, ANSI A119.5.
Installation of any gas-fired equipment should be made by a licensed plumber. A manual shut-

off valve must be installed in an accessible location in the gas line external to the appliance 

for the purpose of turning on or shutting off gas to the appliance (In Massachusetts such shut-

off devices should be approved by the Board of State Examiners of Plumbers & Gas Fitters).
If an external electrical source is utilized, the appliance, when installed, must be electrically 

grounded in accordance with local codes or, in the absence of local codes, with the national 

Electrical Code, ANSI/NFPA 70.

Some  models  are  supplied  with  a  protective  film  on  steel  and  aluminium 

parts. This film must be removed before installing/using the appliance.

R

Summary of Contents for VDGCT212F Series

Page 1: ...C22 1 Canadian Electrical Codes Part 1 and or local codes INSTALLATION IN MANUFACTURED MOBILE HOME The installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CF...

Page 2: ...to light any appliance Do not touch any electrical switch Do not use any phone in your building lmmediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you...

Page 3: ...tion go to www P65Warnings ca gov Dear Customer Thank you for having purchased and given your preference to our product The safety precautions and recommendations reported below are for your own safet...

Page 4: ...supply B Disconnect AC power supply C Disconnect gas line to the inlet pipe D Carefully lift appliance out of cabinet cutout CAUTION The appliance is heavy use care in handling 10 Electrical Requirem...

Page 5: ...placed on the main gas supply line In case of difficulty in the gas valves operation call Service In the case of a prolonged power failure the burners can be used with no restriction In that case fol...

Page 6: ...rol knob 10 Rapid burner 2 control knob 11 Auxiliary burner 3 control knob 12 Semirapid burner 4 control knob 13 Semirapid burner 5 control knob 14 Rapid burner 6 control knob 15 Dual burner 7 control...

Page 7: ...to the symbols printed on the panel achieves the following functions The maximum aperture position permits rapid boiling of liquids whereas the minimum aperture position allows simmer warming of food...

Page 8: ...must 1 Bring a lighted match close to the burner as per side figure and keep it in place until the burner has been ignited 2 Push and turn the knob in an counterclockwise direction up to the LITE HI...

Page 9: ...s to be chosen according to the diameter and volume capacity of the container to be warmed It is important that the diameter of the pots or pans suitably match the heating potential of the burners in...

Page 10: ...he surfaces Important The manufacturer declines all liability for possible damage caused by the use of unsuitable products to clean the appliance WARNING When correctly installed your product meets al...

Page 11: ...must be very carefully cleaned Note To avoid damage to the electric ignition do not use it when the burners are not in place CORRECT REPLACEMENT OF THE AUXILIARY SEMI RAPID AND RAPID BURNERS It is ve...

Page 12: ...prongs of the pan supports must always be centred with the burners figs 3 6 3 7 3 8 3 9 Models VDGCT424FSS VDGCT530FSS VDGCT536FSS The raised portion of the pan supports shall NOT face the sides of th...

Page 13: ...13 3 Mod VDGCT536FSS Fig 3 9 Fig 3 10...

Page 14: ...14...

Page 15: ...15...

Page 16: ...anscription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without...

Reviews: