background image

25

electrical connection

Before any operation of maintenance 

disconnect the appliance from the 

electrical main supply.

If  codes  permit  and  a  separate  ground  wire  is  used,  it  is  recommended  that  a 

qualified electrician determine that the ground path is adequate.

Check with a qualified electrician if you are not sure whether the range is properly

grounded.

Do Not ground to a gas pipe.

A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is required.

A time-delay fuse or circuit breaker is recommended.

It is recommended that a separate circuit serving only this appliance be provided.

The outlet must be checked by a qualified electrician to see if it is wired with correct 

polarity.
This appliance, when installed, must be electrically grounded in accordance with local 

codes.

Recommended ground method

For your personal safety, this range must be grounded.

This range is equipped with a 3-prong ground plug.

To minimize possible shock hazard, the cord must be plugged into a mating 3-prong 

ground-type outlet, grounded in accordance with the National Electrical Code ANSI/

NFPA 70 latest edition and local codes and ordinances.

If a mating outlet is not available, it is the personal responsibility and obligation of the 

customer to have a properly polarized and grounded, 3-prong outlet installed by a 

qualified electrician.

Electrical Shock Hazard

Plug  into  a  grounded  3-prong 

outlet.

Do not remove ground prong.

Do not use an adapter.

Failure to follow these 

instructions  can  result  in  death, 

fire, or electrical shock.

3-prong

ground

plug

Power

supply cord

Ground prong

3-prong polarized

ground-type outlet

Fig. 3.1

3

Summary of Contents for VDFSGG365 Series

Page 1: ...ACTURED MOBILE HOME The installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safe...

Page 2: ...followed exactly a fire or explosion may result causing property damage personal injury or death WARNING WARNING Slide range back so bolt head on the adjustable bracket assembly is under anti tip brac...

Page 3: ...ommercial or communal environment CONVERSION LABEL DATA PLATE The product data plate is attached below the bottom drawer To check the label it is necessary to remove the drawer see Setting the pressur...

Page 4: ...THE APPLIANCE IMPORTANT The use of suitable protective clothing gloves is recommended when handling or installing this appliance WARNING THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER Inst...

Page 5: ...r other codes or in the absence of such codes with the Standard for Recreational Park Trailers ANSI A119 5 4 To eliminate risk of burns or fire by reaching over heated surface units cabinet storage lo...

Page 6: ...ve the countertop for a width of minimum 36 911 mm it has to be centered with the range Side wall cabinets above the range must be a minimum of 18 457 mm above the countertop 4 Air curtain or other ov...

Page 7: ...lacing the 7 8 backguard with the 3 backguard assemble it by using the same screws spacers used for fixing the 7 8 backguard figs 1 3a 1 3b GAS AND ELECTRIC CONNECTION Fig 1 2 Dotted line showing the...

Page 8: ...mum H 0 0 A C A B G E D F A A B G E D F C OVEN VENT OVEN VENT H H Maximum height of cabinetry immediately adjacent to the range from floor to countertop Depending on the height of the feet adjustment...

Page 9: ...6 Fig 1 6 LEVELLING THE COOKER The cooker may be levelled by screwing the lower ends of the feet IN or OUT fig 1 7 It is important to observe the directions of figure 1 7 1 31 32 50 mm 0 mm 0 Fig 1 7...

Page 10: ...p bracket and ensure they are properly fitted together to prevent the range from tipping To fit the anti tip bracket 1 Thread the bolt through the adjustable bracket and fix in place using the two sup...

Page 11: ...two nuts are well tightened after any adjustments IMPORTANT Use the proper screws to fix the stability bracket in place according to the type of material on the floor and or wall Before drilling and h...

Page 12: ...nt guard as shown in figure 1 12 1 Remove the backguard A 2 Remove the pan supports the burner caps and the flame spreaders 3 Unscrew cooktop fixing screws B and C in figure below 4 Remove the cooktop...

Page 13: ...so can result in death explosion or fire Fig 2 1 All gas connections must be made according to national and local codes This gas supply service line must be the same size or greater than the inlet lin...

Page 14: ...the extension pipe interposing the gasket supplied The regulator cover must be oriented toward the front side of the range IMPORTANT use two wrenches to tighten the connection Insert the extension pi...

Page 15: ...front side of the range IMPORTANT use two spanners to tighten the connection STEP 4 Fix the extension pipe support bracket onto the back of the range using the two supplied screws Take care to ensure...

Page 16: ...ing Gasket Range manifold Manifold male pipe fitting 1 2 G cylindrical ISO 228 1 male E x t e n s i o n p i p e f e m a l e p i p e f i t t i n g 1 2 G cylindrical ISO 228 1 female Gasket Extension pi...

Page 17: ...be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1 2 PS...

Page 18: ...ing to the INJECTORS TABLE The nozzle diameters expressed in hundredths of a millimetre are marked on the body of each injector CAUTION Save the injectors removed from the appliance for future use SET...

Page 19: ...y the safety catches will automatically hook into place Fig 2 10 Pressure regulator REGULATOR COVER NATURAL GAS REGULATION LP PROPANE REGULATION Fig 2 9 To set the pressure regulator fig 2 9 1 Unscrew...

Page 20: ...ation of the primary air 2 INJECTORS TABLE NOMINAL POWER REDUCED POWER LP PROPANE 11 W C P NATURAL GAS 4 W C P BURNERS BTU hr BTU hr injector 1 100 mm injector 1 100 mm Semirapid SR 8000 1500 85 139 T...

Page 21: ...adjustment is correct Inside crown of DUAL burner Light the DUAL burner Set the gas valve to position minimum rate of inner crown Remove the knob With a thin screwdriver turn the regulation screw R2 u...

Page 22: ...5 Withdraw the burner as shown in figure 2 16 Using a 7 mm box spanner unscrew the injector indicated by the arrow in fig 2 16 and replace it with a new one selected in accordance with the Injectors t...

Page 23: ...shown in figure 2 18 Using a 7 mm box spanner unscrew the injector indicated by the arrow in fig 2 18 and replace it with a new one selected in accordance with the Injectors table Then replace the bu...

Page 24: ...you obtain a flame of 3 4 mm in height The flame should not go out even when passing suddenly from maximum to minimum flame N B For LP PROPANE gas the by pass screw must be fixed thoroughly Afterregu...

Page 25: ...installed must be electrically grounded in accordance with local codes Recommended ground method For your personal safety this range must be grounded This range is equipped with a 3 prong ground plug...

Page 26: ...molimitateur de s curit PA Cooktop burners ignition switches group Groupe d interrupteurs d allumage br leurs de la table de travail A Oven broil ignition coil G n rateur d allumage four gril A1 Cookt...

Page 27: ...27...

Page 28: ...anscription errors in the present booklet The manufacturer reserves the right to make all modifications to its products deemed necessary for manufacture or commercial reasons at any moment and without...

Reviews: