SETTING THE BURNER MINIMUM
When switching from one type of gas to another, the minimum flow rate must also be correct: the flame should not go out even when
passing suddenly from maximum to minimum flame.
To regulate the flame (fig. 2.14) follow the instructions below:
Triple-ring and semirapid burner
•
Light the burner.
•
Set the gas valve to
position (minimum rate).
•
Remove the knob.
•
With a thin screwdriver, turn the regulation screw “
R
1
” until adjustment is correct.
Inside crown of DUAL burner
•
Light the DUAL burner.
•
Set the gas valve to
position (minimum rate of inner crown).
•
Remove the knob
•
With a thin screwdriver, turn the regulation screw “
R
2
” until adjustment is correct.
Outside crown of DUAL burner
•
Light the DUAL burner.
•
Set the gas valve to
position (minimum rate of outer crown and maximum rate of inner crown).
•
Remove the knob.
•
With a thin screwdriver, turn the regulation screw “
R
3
” until adjustment is correct.
For LP/PROPANE gas, tighten the adjustment screws completely.
R
1
Regulation screw (Triple-ring and semirapid burner)
R
2
Regulation screw (Inner crown of dual burner)
R
3
Regulation screw (Outer crown of dual burner)