Vernier Go Direct Photogate Manual Download Page 2

2

Using the Product

A. Power button

B. Charging LED indicator
C. Bluetooth LED indicator

D. Laser gate LED indicator

E. Laser gate photodiode

F. Gate 1 LED indicator

G. Sensor ID number
H. Gate 2 LED indicator

I. Gate 1 photodiode

J. Gate 2 photodiode

K. Bar tape guide

L. Daisy-chain accessory port

M. Micro-USB port

N. Gate 2 infrared emitter diode
O. Gate 1 infrared emitter diode

P. 1/4-20 mounting nut

Q. Battery door

R. Pulley bracket attachment point

S. Ultra pulley attachment points

Sensor Channels

Connect the sensor following the steps in the Getting Started section of this user
manual. Go Direct Photogate has multiple sensor channels that provide a variety
of data options for measuring the motion of an object. The sensor channels
include

l

Object Velocity

l

Object Acceleration (multiple flags)

l

Gate 1 – Gate State

l

Gate 2 – Gate State

l

Laser Gate – Gate State

l

Remote Gate – Object Velocity

l

Remote Gate – Object Acceleration

l

Gate 1/Remote Gate – Timing

l

Laser Gate/Remote Gate – Timing

Powering the Sensor

Turning on the sensor

Press the power button once. LED indicator next
to the Bluetooth icon flashes red when unit is
on.

Putting the sensor in sleep
mode

Press and hold the power button for more than
three seconds to put into sleep mode. LED
indicators are off when sleeping.

Connecting the Sensor

See the following link for up-to-date connection information:

www.vernier.com/start/gdx-vpg

Connecting via Bluetooth Wireless Technology

Ready to connect

LED indicator next to the Bluetooth icon flashes
red when sensor is awake and ready to connect
to software.

Connected

LED indicator next to Bluetooth icon flashes
green when sensor is connected to software via
Bluetooth.

Connecting via USB

Connected and charging

LED indicator next to the battery icon is solid
orange and the LED indicator next to the
Bluetooth indicator is off when sensor is con-
nected to software via USB and the unit is char-
ging.

Connected, fully charged

LED indicator next to the battery icon is solid
green and the LED indicator next to the
Bluetooth icon is off when sensor is connect to
software via USB and is fully charged.

Charging via USB,
connected via Bluetooth

LED indicator next to the battery icon is solid
orange and the LED indicator next to the
Bluetooth icon flashes green when the sensor is
connected to software via Bluetooth and the unit
is charging.

Identifying the Sensor

Use the Identify feature to flash the LED indicator next to the Bluetooth icon
on the sensor to which you are connected. In Graphical Analysis 4, Identify is
accessed from Sensor Information. In LabQuest App, Identify is accessed by
tapping the sensor meter, then tapping Go Direct.

Summary of Contents for Go Direct Photogate

Page 1: ...or velocity acceleration and timing measurements of objects passing through the gate The object blocks infrared beams as it passes through the gate Motion data can be determined from the timing of bea...

Page 2: ...into sleep mode LED indicators are off when sleeping Connecting the Sensor See the following link for up to date connection information www vernier com start gdx vpg Connecting via Bluetooth Wireless...

Page 3: ...ed Sensor Channels The object based sensor channels are unique to Go Direct Photogate These sensor channels make use of the double gate design for measurement of velocity and acceleration The object b...

Page 4: ...ectly to your device Experiments Using Go Direct Photogate Go Direct Photogates can be used for several experiments in the books Physics state channels can be used with Photogate Timing modes for addi...

Page 5: ...ley and pulley bracket l Mounted on a dynamics track using a photogate bracket and pulley l Used with photogate bar tape l Mounted on the original Centripetal Force Apparatus with Vernier Advanced Phy...

Page 6: ...00 Micro USB Cable CB USB MICRO USB C to Micro USB Cable CB USB C MICRO Accessory Rod ACC ROD Specifications Infrared source Peak at 880 nm Gate width 77 5 mm Internal gate separation 20 mm Distance f...

Page 7: ...that this product is disposed of correctly you help prevent potential negative consequences on human health or on the environment The recycling of materials will help to conserve natural resources For...

Reviews: