38
No deodoriser
being
dispensed.
Blockage in feed
pipework.
Check pipework for blockage- clean.
Dispensing valve
failure.
Check solenoid valve for blockage –
clean.
Check non return valve for blockage –
clean.
Deoderisor Tank empty
Check fill level and display icon
functions.
Check level switch - replace.
Check non return valve for blockage –
clean.
Display screen
blank.
No power to the
screen.
Check connections from pcb and at the
display ensure all pins engaged -
replace
Check power is on at the pcb-
illuminated neon.
Display blank – replace display.
Fault 11
Fault 12
Summary of Contents for Vortex
Page 1: ...Issue No 2 ...
Page 8: ...8 Figure 1 Dimensions of the Vernacare Vortex ...
Page 20: ...20 7 Lid Arm Assembly Figure 5 Lid Arm Assembly ...
Page 25: ...25 11 Water Distribution Figure 9 Water Distribution ...
Page 27: ...27 12 Electrical Circuit Figure 10 Electrical Circuit ...